HP Virtual Connect for c-Class BladeSystem Version 3.00 User Guide for Integrity BL8x0c i2 Server Blades
Hardware information screens  127 
Causes for INCOMPATIBLE status 
When a module status is INCOMPATIBLE, details can be viewed in the System log ("System Log screen" 
on page 49). The system log provides information about why a module is marked incompatible so that 
proper corrective action can be taken. 
Following is a list of reasons why a module might be INCOMPATIBLE and the suggested corrective 
action. 
•  Module adjacency 
Typically, a module can only be in a bay next to a module of the same type. See the installation 
guidelines in the HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide. 
If a module is next to another module that it is not compatible with, both modules will be labeled as 
INCOMPATIBLE, since the rule applies to both modules. 
Corrective action: Remove the adjacent incompatible modules and replace with modules that are 
compatible next to each other. 
•  Module replacement 
If an interconnect module is being used by the domain, is physically removed, and then another 
module is put in the same bay, the new module must be the same type as the module previously in 
the bay.  
If the physically removed module was NOT being used by the domain, the module can be replaced 
with a module of a different type. 
VC-Enet modules are considered in use by the domain under the following conditions: 
o  Uplinks or downlinks are being used by networks/profiles 
o  The module is in interconnect bay 1 or bay 2 of the primary enclosure 
VC-FC Modules In-Use by the Domain modules are considered in use by the domain if uplinks or 
downlinks are being used by fabrics or profiles 
Corrective action: Remove the incompatible module and replace with the same module that 
previously existed. For more information, see "Module removal and replacement (on page 141)." 
•  Firmware version 
Only modules with firmware versions supported by the firmware running on the primary module are 
compatible. All other versions of firmware modules cause the module to be marked as 
INCOMPATIBLE. 
Corrective action: Use VCSU to update incompatible modules to the appropriate firmware versions 
for the domain. 
•  FC bay groups 
In a multi-enclosure environment, all enclosures must have the same FC module configuration. For 
more information, see the multiple enclosure guidelines in the HP Virtual Connect for c-Class 
BladeSystem Setup and Installation Guide. 
Corrective action: Remove the incompatible module and replace it with the correct module for the FC 
bay group that already exists. 
•  In a c3000 enclosure, FC modules are not supported in bay 2. 