HP Virtual Connect for c-Class BladeSystem Version 3.00 User Guide for Integrity BL8x0c i2 Server Blades
Hardware information screens  142 
2. 
Remove all uplinks and downlinks. 
3.  Replace the module. 
Administrative module removal 
The Remove from Domain feature enables users to remove an interconnect module from the Virtual 
Connect domain without having to delete the entire domain, or having the bay permanently configured 
for a specific interconnect module type.  
Removing a VC-Enet module and installing it in another enclosure causes the configuration information on 
that module to be cleared. This action prevents a configured spare from overwriting configuration data in 
another enclosure. 
To temporarily remove the module from the domain, do not click Remove from Domain. Simply re-install it 
into the enclosure. 
To permanently remove the module from the Virtual Connect domain, be sure the following conditions are 
met: 
NOTE: The attachment of stacking link cables to a module does not prevent a Remove from 
Domain action.  
•  VC-Enet conditions: 
o  The user must have Domain privileges. 
o  The module must be physically removed from the bay. 
o  The interconnect bay must remain empty for this procedure. 
o  The module uplink and downlink ports cannot be in use by networks, uplink sets, or profiles 
(including FC profiles) in the enclosure. 
o  Port monitoring cannot be enabled on that bay. 
•  VC-FC conditions: 
o  The user must have Domain privileges. 
o  The module must be physically removed from the bay. 
o  The interconnect bay must remain empty for this procedure. 
o  Change all fabrics on that module to Unassigned for all Virtual Connect profile configurations. 
•  If removing an FC module from a multi-enclosure domain, all FC modules in that bay in each 
enclosure must be missing. Removing one of the missing modules removes the module from all 
enclosures. 
If these conditions are met, click Remove from Domain. 
If these conditions are not met, the Remove from Domain button is not available, or an error message 
appears. 
If a VC-Enet module is restarted from a power-cycle or reboot, or the module is removed and inserted, a 
link might not be re-established between the module and the ports of an NC364m mezzanine card. If the 
server is rebooted, the link is established on all ports on both sides of the connection. Manually toggling 
the link from the server should also restore the link. 