HP Virtual Connect for c-Class BladeSystem Version 3.00 User Guide for Integrity BL8x0c i2 Server Blades
Hardware information screens  144 
Icon  Operational state  Meaning  Corrective action 
(blue) 
Unavailable 
Device is active but unable to 
provide service. 
Attempt to re-establish connection. 
(yellow) 
Degraded 
Device is partially operational, 
but capacity is lost. 
Check and correct the Onboard 
Administrator error condition. 
(orange) 
Misconfigured  Device has a configuration error. 
Correct the Virtual Connect Manager 
configuration attributes. 
(orange) 
Incompatible 
Device does not match the 
configuration. 
Remove the incorrect hardware. 
Insert the correct module. 
(orange) 
No communication 
Cannot communicate with the 
device. 
Check the physical connections and 
IP address. 
Missing 
Device is configured but not 
accessible. 
Insert the correct hardware module. 
Failed 
Device is not operational because 
of an error. 
Reset the device or application, or 
replace the device. 
Interconnect Bay OA Communication Status icon definitions 
Icon  Operational state  Meaning  Corrective action 
OK  Device is fully operational.  None 
Failed 
Cannot communicate with the 
device. 
Do one or more of the following: 
•
  Reset the interconnect module. 
•
  Check if the physical device is 
properly seated in the bay. 
•
  Check the IP address. 