HP Virtual Connect for c-Class BladeSystem Version 3.00 User Guide for Integrity BL8x0c i2 Server Blades
Domain management  44 
Trap categories and required administrative privileges 
In general, users with Domain privileges can manage any SNMP operations. Users with Network 
privileges can manage Ethernet operations, and users with Storage privileges can manage FC operations. 
The following table provides a summary of trap categories and the required administrative privileges. 
Trap Category  Domain  Network  Storage 
VC-Enet Port Status  X  X  — 
VC-Enet Port Threshold  X  X  — 
VC-Enet Other  X  X  — 
VC-FC Port Status  X  —  X 
VC-FC Other  X  —  X 
VCM Legacy  X  —  — 
VCM Security  X  —  — 
VCM Domain Status  X  —  — 
VCM Network Status  X  —  — 
VCM Fabric Status  X  —  — 
VCM Profile Status  X  —  — 
VCM Server Status  X  —  — 
VCM VC-Enet Status  X  —  — 
VCM VC-FC Status  X  —  — 
To enable or disable SNMP on a VC-Enet module, Domain or Network privileges are required. To enable 
or disable SNMP/SMI-S on a VC-FC module, Domain or Storage privileges are required. 
Trap severities 
Users can configure the severity of traps to be sent to each trap destination. The levels are listed below in 
decreasing order of severity:  
•  CRITICAL—The component cannot manage installed VC components. 
•  MAJOR—One or more of the component's subsystems are not operating properly, causing serious 
disruption to functions. 
•  MINOR—One or more of a component's subsystems are not operating properly, causing slight 
disruption to functions. 
•  WARNING—The component has a potential problem. 
•  INFO—Operational information on the fully functioning component. 
•  UNKNOWN—VC Manager has not yet established communication with the component. 
•  NORMAL—The component is fully functional. 
Trap severities are only supported for VC-Enet or VCM traps. 