HP Virtual Connect for c-Class BladeSystem Version 3.00 User Guide for Integrity BL8x0c i2 Server Blades
Storage management  82 
Storage management 
Storage overview 
The Virtual Connect Fibre Channel modules enable the c-Class administrator to reduce FC cabling by 
making use of N_Port_ID virtualization (NPIV). The HP VC-FC acts as an HBA aggregator where each 
NPIV-enabled N-port uplink can carry the FC traffic for multiple HBAs. 
Because it uses an N-port uplink, it can be connected to data center Brocade, McData, Cisco, and Qlogic 
FC switches that support the NPIV protocol. When the server blade HBAs log in to the fabric through the 
VC-FC module, the HBA WWN is visible to the FC switch name server and can be managed as if it was 
connected directly. 
IMPORTANT: The HP Virtual Connect Fibre Channel modules must be connected to a data 
center Fibre Channel switch that supports N_Port_ID virtualization (NPIV). See the switch 
firmware documentation for information to determine whether a specific switch supports NPIV 
and for instructions on enabling this support.  
The VC-FC module has either four or eight uplinks. Each uplink is completely independent of the other 
uplinks and has a capability of aggregating up to 16 physical server HBA N-port links into an N-port 
uplink through the use of NPIV. 
In previous versions of Virtual Connect, a one-to-one relationship existed between VC-FC uplinks and 
external FC SAN fabrics. Beginning with version 1.31 of Virtual Connect Manager, users can group 
multiple VC-FC module uplinks logically into a Virtual Connect fabric when attached to the same Fibre 
Channel SAN fabric. Using this feature, users can access more than one FC SAN fabric in their data 
center, plus have a flexible and fully redundant way to connect server blades to Fibre Channel SANs. 
User can connect to up to four SAN fabrics from one VC-FC module, and up to eight SAN fabrics from 
one HP VC 8Gb 24-Port module. 
Virtual Connect Fabric 
By default, all of the VC-FC uplinks are grouped into a single fabric, distributing connectivity from all 16 
server blades in the enclosure. If a port in the group becomes unavailable, hosts logged in through that 
port are reconnected to the fabric through the remaining ports in the group, resulting in auto-failover. 
However, users can redistribute the connections manually. 
To form a Virtual Connect fabric correctly, participating uplinks must be connected to the same SAN 
fabric. The WWN of the principle fabric switch indicates connectivity to the same SAN fabric in Virtual 
Connect. 
The module uses dynamic login distribution to provide an uplink port path failover that allows server 
connections to failover within the Virtual Connect fabric. Server connections are redistributed across all 
available (currently logged into the external SAN) uplink ports. 