Storage management  85 
Task  Description 
Set the uplink port speed 
After an uplink port has been added, click the drop-down arrow in 
the Configured Speed field, and then select a speed. 
Delete an uplink port 
Left-click an uplink port row to select it, right-click to display a menu, 
and then select Delete Port. 
Save changes and remain on this 
screen 
Click Apply. 
Clear the current, unsaved changes 
and return to the home page 
Click Cancel. 
Enabling NPIV on the fabric switch 
When installing the VC-FC module, NPIV must be enabled on the fabric switch that is attached to the VC-
FC module uplinks before the server blade HBAs can log in to the fabric. See the Fibre Channel switch 
firmware documentation for information on whether it supports NPIV and for instructions on enabling this 
support. 
Brocade switch 
Most Brocade Fibre Channel switches running Fabric OS 5.1.0 or later will support NPIV. All Brocade 
4Gb- and 8Gb-capable Fibre Channel switches are configured with NPIV enabled by default. 
When not enabled by default, use the portCfgNPIVPort command within the Brocade switch 
command line interface to enable NPIV. For additional information on usage of the portCfgNPIVPort 
command, see the Brocade switch firmware documentation. 
To enable NPIV on all other Brocade Fibre Channel Switches, use the following Fabric OS CLI procedure: 
1.  To enable or disable NPIV on a port-by-port basis, use the portCfgNPIVPort command. 
Example: To enable NPIV on port 10, enter following command: 
switch:admin> portCfgNPIVPort 10, 1 
2.  To specify the number of virtual N_Port_IDs per port or per switch, use the configure command 
with either of the following parameters: 
switch.login.perPortMax—Use this parameter to set the number of virtual N_Port_IDs per port 
to a value between 0 and 255. The default setting is 126. 
switch.login.perSwitchMax—Use this parameter to set the number of virtual N_Port_IDs per 
switch to a value between 0 and (126 * number of ports). The default setting is (15 * number of 
ports). 
Example: 
switch:admin> switchdisable 
switch:admin> configure 
Configure... 
Fabric parameters (yes, y, no, n): [no] 
Virtual Channel parameters (yes, y, no, n): [no] 
F-Port login parameters (yes, y, no, n): [no] y 
Maximum logins per switch: (1..4032) [4032] 2048 