HP Virtual Connect for c-Class BladeSystem Version 3.30 User Guide
Virtual Connect fabrics  108 
•  Multi-enclosure domain 
The following table describes the columns and fields within the Define SAN Fabric screen. 
Column  Description 
Fabric Name 
Descriptive name for the virtual fabric. Do not use spaces. 
Login Re-Distribution 
Login Re-distribution setting for the fabric. For all standard VC-FC modules, this is 
always Manual. For FlexFabric modules, this can be set as described in "Login 
re-distribution (on page 109)." 
Configured Speed 
Speed of the uplink ports, available after a port has been added. Valid values once 
allowed are 2Gb, 4Gb, 8Gb, and Auto. 
Uplink Port 
Number of the FC module uplink port 
Bay 
Enclosure bay selected for the SAN fabric. Only uplinks on the same bay can be in the 
same SAN fabric. 
Port Status 
Shows the link status, link speed, and connectivity of the port. If If the port is unlinked 
and no connectivity exists, the cause is displayed. For more information about possible 
causes, see "Port status conditions (on page 203)." 
Speed 
Port speed for the uplink ports in the fabric 
Connected To 
WWN of the principal switch on the SAN fabric that this port is connected to on the 
other end 
Action 
Perform delete operations 
The following table describes the available actions in the Define SAN Fabric screen. Clicking another link in 
the pull-down menu or left navigation tree causes the current edits that have not been applied to be lost. 
Task  Description 
Create a fabric name 
Type a name in the Fabric Name field. Do not use spaces. 