HP Virtual Connect for c-Class BladeSystem Version 3.30 User Guide
Virtual Connect modules  181 
Row  Description 
Enclosure Name 
Name of the enclosure (assigned through the Onboard Administrator) 
Bay 
Number of the bay being summarized on this screen 
Module Host Name 
Includes controls that enable you to set a custom host name for the module and 
reset the module 
Power Status/Control 
Power state of the device 
The following table describes the rows within the Interconnect Bay Information table in the Bay Summary 
screen. 
Row  Description 
Part Number 
The part number to be used when ordering an additional module of this type 
Product Name 
The common descriptive name of the module 
Serial Number 
The unique serial number of the module 
Dip Switch Setting 
The current physical setting of the system maintenance switches in a 
hexadecimal format, where the least significant four bits of the value 
correspond to the four switches and a bit value of 1 indicates the switch is in 
the "on" position. 
Spare Part Number 
The part number to be used when ordering a replacement module of this type
Manufacturer 
The manufacturer of the module 
Firmware Rev 
The current firmware revision of the module 
The following table describes the columns within the Uplink Port Information table in the Bay Summary 
screen. 
Column  Description 
Label 
Uplink port number 
Network(s) 
Network name or the name of the shared uplink associated with this port 
Status 
Shows the link status, link speed, and connectivity of the port. If the port is 
unlinked and no connectivity exists, the cause is displayed. For more 
information about possible causes, see "Port status conditions (on page 203)."
Connector Type 
Displays the physical type of the faceplate connector, type of pluggable 
module if one is present, or "Internal" to indicate the inter-
switch link is active 
on the VC-Enet module. 
LAG ID 
Identifies the group of ports that have been aggregated together to form an 
802.3ad Link Aggregation Group. This ID is unique only within a single 
VC-Enet module, meaning the same LAG ID can be used on different VC-Enet 
modules, but it is only meaningful for ports within the same VC-Enet module. 
Connected to 
Displays the MAC address of the device that this port is connected to on the 
other end. The remote device must support LLDP to display this information. 
Detailed Statistics 
Click to display detailed statistics about this port. 
The following table describes the columns within the Server Port Information table in the Bay Summary 
screen. 
Column  Description 
Label 
Server side port number (determined by the device bay and NIC) 
Flex NIC 
Flexible network interface card port 
Physical server 
Number of the device bay and a description of the installed server blade 