HP Virtual Connect for c-Class BladeSystem Version 3.30 User Guide
Virtual Connect modules  198 
Icon  Operational state  Meaning  Corrective action 
(blue) 
Initializing  Device is initializing.  Wait until initialization is complete. 
(This icon should only be seen at 
startup.) 
(blue) 
Profile pending  Device has a pending profile 
assignment. 
Turn server power off and apply the 
new profile. 
(yellow) 
Degraded  Device is partially operational, but 
capacity is lost. 
Check and correct the Onboard 
Administrator error condition. 
(orange) 
Misconfigured  Device has a configuration error.  Correct the Virtual Connect Manager 
configuration attributes. 
(orange) 
Incompatible  Device does not match the 
configuration. 
BIOS level is not at a level that supports 
Virtual Connect. 
(orange) 
No communication  Cannot communicate with the 
device. 
Check the physical connections and IP 
address. 
Missing  Device is configured but not 
accessible. 
Insert the correct hardware module. 
Failed  Device is not operational because 
of an error. 
Reset the device or application, or 
replace the device. 
Server Bay OA Communication Status icon definitions 
Icon  Operational state  Meaning  Corrective action 
OK  Device is fully operational.  None 
Failed  Cannot communicate with the 
device. 
Do one or more of the following: 
•
  Reset the interconnect module. 
•
  Check if the physical device is 
properly seated in the bay. 
•
  Check the IP address. 