HP Virtual Connect for c-Class BladeSystem Version 3.30 User Guide
Virtual Connect networks  90 
Field name  Description 
Smart Link (on page 71) 
Shows whether Smart Link is enabled (checked) or disabled (unchecked)
Private Network ("Private Networks" on 
page 71) 
Shows whether this network is designated (checked) or not designated 
(unchecked) as a private network 
Enable VLAN Tunneling ("VLAN 
Tunneling Support" on page 71) 
Shows whether VLAN tunneling is enabled (checked) or disabled 
(unchecked) 
External Uplink Ports 
Use Shared Uplink Set 
Enables the selection of a shared uplink set to be used as the uplink port 
for this network. For more information, see “Shared uplink sets and 
VLAN tagging (on page 70)." 
Port 
Network port locations (enclosure, bay, and port numbers) 
Port Role 
Applicable when Failover Connection Mode is selected. The port can be 
designated as Primary or Secondary. 
Port Status 
Shows the link status, link speed, and connectivity of the port. If the port 
is unlinked and no connectivity exists, the cause is displayed. For more 
information about possible causes, see "Port status conditions (on page 
203)." 
Connector Type 
Displays the type of connector on the port; for example, RJ-45 
Connected to 
If the port is connected to a switch that supports LLDP, the switch MAC 
address and switch port number appear. A link is provided to obtain 
more information about the far-end switch port. 
PID 
When selected, this option sets/clears the port identifier color as blue on 
the VC E-
net module to aid in the location of the specific uplink. The PID 
status for the overall network also appears. 
Speed/Duplex 
Pull-down menu to specify the speed and duplex (where applicable) of 
the uplink port 
Network Access Groups 
Displays the Network Access Groups that include this network. 
The following table describes the available actions in the Edit Ethernet Network screen. Clicking another link 
in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost. 
Task  Action 
Modify network color 
Select a color from the Color pull-down menu. 
Modify network label 
Type a label in the Labels field, and then press Enter
. A network can have 
up to 16 labels. Labels cannot contain spaces and are limited to 24 
characters. 
Enable or disable Smart Link on the 
network being defined 
Select the Smart Link checkbox. 
Designate or do not designate the 
network as a private network 
Select the Private Network checkbox. 
Enable or disable VLAN tunneling 
Select the Enable VLAN Tunneling checkbox. 
Enable or disable the network 
Select the Enabled checkbox. 
Set a custom value for preferred link 
connection speed or maximum link 
connection speed 
Select the Advanced Network Settings checkbox. 
Add an external uplink port to the 
network 
Use the cascading menu to select a port, and then click Add Port. 
Change the uplink interface port speed 
or disable the port 
Click the pull-down box under Speed/Duplex, and then select a setting.
Change the connection mode 
Click the down arrow in the box next to Connection Mode, and then 
select Auto or Failover. For a description of these modes, see "
Defining 










