HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.01 User Guide
Command line  48 
Item  Description 
->reboot server * -ForceOnTimeout -timeout=180 
Reboots all servers using the ForceOnTimeout option and a custom timeout 
->reboot server * 
Reboots all servers in the domain 
->reboot server enc0:* 
Reboots all servers in a specific enclosure 
->reboot server enc0:1 
Reboots a specific multi-blade server that occupies bays 1-4 of the primary 
enclosure 
Item  Description 
show server
Display all servers in the domain. 
Syntax 
show server [<ServerID|*>] 
Parameter 
ServerID (optional) 
The reference ID of a server in the domain. The format of the server ID is 
<EnclosureID:Bay>. If the EnclosureID is not provided, then the primary or local 
enclosure is used by default. 
For a multi-blade server, the ServerID must be that of the monarch bay. This is the ID 
shown in the summary listing. 
Examples 
->show server 
Displays a summary listing of all servers 
->show server * 
Displays detailed information for all servers 
->show server enc2:* 
Displays detailed information for all servers in a specific enclosure 
->show server enc0:4 
Displays detailed information for the specific server in device bay 4 of an enclosure 
named "MyEnclosure" 
->show server enc0:5 
Displays detailed information for a specific multi-blade server that occupies bays 
5-8 of the primary enclosure 
serverid 
Manage virtual Server ID configuration settings. 
Supported actions: help, set, show 
Item  Description 
set serverid 
Modify Virtual Server ID domain settings. The serial number attributes can be 
changed only in one of the following scenarios: 
•
  Virtual Server ID source is Factory-Default. 
•
  Virtual Server ID source is VC-Defined or User-
Defined, but no profiles are using 
server IDs from this source. 
•
  Virtual Server ID source is User-Defined, and this range is being extended by 
lowering the start or increasing the end values. 
Syntax 
set serverid Type=Factory-Default 
set serverid Type=VC-Defined [PoolID=<1-64>] 
set serverid Type=User-Defined Start=VCX01nnnnn 