HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.01 User Guide
Command line  60 
Item  Description 
Syntax 
show systemlog [-Last=<n>] [-First=<n>] [-Pause=<n>] 
Options 
Last 
Display the last n 
records. If this option is specified and no value is provided, the 
default is the last 10 records. 
First 
Display the first n records. If this option is specified and no value is provided, the 
default is the first 10 records. 
Pause 
Number of records to be viewed before prompting for key press. Valid values 
include numbers between 1 and 40. 
Examples 
->show systemlog 
Displays the entire system log 
->show systemlog -pause=8 
Displays the system log, eight records at a time 
->show systemlog -first=12 
Displays the first twelve records from the system log 
->show systemlog -last=8 
Displays the last eight records from the system log 
->show systemlog -last=20 -pause=6 
Displays the last twenty records from the system log, six records at a time 
To add a remote target, see "add log-target (on page 35)." 
uplinkport 
Manage interconnect module uplink ports. 
Supported actions: add, help, remove, set, show 
Item  Description 
add uplinkport
Add a new uplink port to an existing network or a shared uplink port set. 
Syntax 
add uplinkport <PortID> [Network=<NetworkName> | 
UplinkSet=<UplinkSetName>] 
[Speed=<Auto|10Mb|100Mb|1Gb|10Gb|Disabled>] 
[Role=<Primary|Secondary>]
Parameter 
PortID (required) 
The ID of an uplink port to add. The ID is a combination of the enclosure name, 
interconnect bay, and port number in a single descriptor. The format of the port ID is 
"
<EnclosureID>:<InterconnectBay>:<PortNumber>
". 
Properties 
Network 
(required) 
The name of an existing network to which the port is added if the uplink set name has 
not been specified. 
UplinkSet 
(required) 
The name of an existing shared uplink port set to which the port is added if the network 
name has not been specified. 
Speed (optional) 
Specifies the port speed for the port (optional). Valid values include "Auto", "10Mb", 
"100Mb", "1Gb", "10Gb", and "Disabled". If not specified, the default port speed is 
"Auto". 
If there is no connector present on the uplink port, only "Auto" and "Disabled" can be 
configured as a possible speed. Speed restrictions apply. 
Role (optional) 
The role played by the port if the connection mode of the network or shared uplink set 
is selected as "Failover". The default is "Primary". 