Command line  26 
Item  Description 
uplink sets can transmit and receive untagged frames only.  
The "Map" option enables the user to add more than one network to a single 
Ethernet port for the server profiles, and also enables the user to specify VLAN 
mapping between server tags and VC networks. Also, Ethernet networks with 
dedicated uplinks can transmit and receive untagged frames only. 
SharedServerVLanId 
(optional) 
Enables or disables the option to force server ports connected to multiple VC 
Ethernet networks to use the same VLAN mappings as those used by 
corresponding shared uplink sets. Valid values include "true" and "false". 
Setting the value to "true" restricts the server network connections to be selected 
from a single shared uplink, and the VLAN ID cannot be modified. 
Setting the value to "false" enables the user to select any VC Ethernet network for 
the server Ethernet connections, and VLAN ID mappings can be modified to 
ensure uniqueness. 
SharedServerVLanId can be "true" only if VLanTagControl is set to "Map". 
PrefSpeedType 
(optional) 
The default connection speed for any Ethernet connection using multiple 
networks. Valid values include "Auto" and "Custom". "Custom" allows the user 
to configure the preferred speed. The default value is "Auto". 
PrefSpeed (required if 
PrefSpeedType is 
Custom)
The default connection speed for any Ethernet connection using multiple 
networks. Valid values range from 100Mb to 10Gb in 100Mb increments. 
MaxSpeedType 
(optional) 
Maximum connection speed for any Ethernet connection using multiple networks. 
Valid values include "UnRestricted" and "Custom". "Custom" allows the user to 
configure the preferred speed. The default value is "Unrestricted". 
MaxSpeed (required if 
MaxSpeedType is 
Custom)
The maximum connection speed for any Ethernet connection using multiple 
networks. Valid values range from: 100Mb to 10Gb in 100Mb increments. 
Examples 
->set enet-vlan VLanTagControl=Map SharedServerVLanId=true 
Sets the VLanTagControl to Map and SharedServerVLanId to Enabled 
->set enet-vlan PrefSpeedType=Custom PrefSpeed=500 
MaxSpeedType=Custom MaxSpeed=2500 
Sets the preferred connection speed for all connections using multiple networks to 
500Mb, and the maximum connection speed to 2.5Gb 
Item  Description 
show enet-vlan 
Display general Ethernet VLAN configuration settings. 
Syntax 
show enet-vlan 
Example 
->show enet-vlan 
Displays Ethernet VLAN configuration settings 
external-manager 
Manage external manager settings and information. 
Supported actions: remove, help, set, show 
Item  Description 
remove 
external-manager 
Remove an existing external manager (VCEM) and regain local management 
profile control of the domain. 
When releasing the profile control, it is mandatory to specify values for each 