HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.10/3.15 User Guide
Command line  37 
Item  Description 
show igmp
Display Ethernet IGMP Snooping settings. 
Syntax 
show igmp 
Example 
->show igmp 
Displays IGMP Snooping settings 
interconnect 
Manage I/O interconnect modules. 
Supported actions: help, remove, show 
Item  Description 
remove interconnect 
Remove an interconnect module from the domain. Normally this command is 
used if a module has been physically removed from the enclosure. To be 
removed, the module must not be currently in use by any element in the domain.
Syntax 
remove interconnect <ModuleID|*> 
Parameter 
ModuleID(required) 
The ID of the module to remove. The ID format is 
<EnclosureID>:<BayNumber>. To display a list of the IDs corresponding to 
modules in the domain, use the 
show interconnect
 command. 
Examples 
->remove interconnect enc0:2 
Removes a specific interconnect module (bay 2) from the domain 
->remove interconnect * 
Removes all interconnect modules from the domain that are not present physically 
in any enclosure 
->remove interconnect enc0:* 
Removes all interconnect modules that are not physically present in a specific 
enclosure 
->remove interconnect *:2 
Removes interconnect modules (bay 2) from the domain that are not physically 
present in all enclosures 
Item  Description 
show interconnect
Display all interconnect modules known to exist in the domain. 
Syntax 
show interconnect [<ModuleID>|*] 
Parameter 
ModuleID (optional) 
The ID of the interconnect module. “*” displays detailed view of all the modules 
in the VC domain. If not specified, a summary output of all the modules appears.
Examples 
->show interconnect 
Displays a summary listing of all interconnect modules 
->show interconnect * 
Displays detailed information for all interconnect modules 
->show interconnect *:5 
Displays detailed information for all enclosures with interconnect modules in 










