HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.30 User Guide
Configuring the Virtual Connect domain using the CLI  141 
CAUTION: To avoid storage networking issues and potential loss of data associated with 
duplicate WWNs on a FC SAN fabric, plan carefully when allowing Virtual Connect to assign 
server blade WWNs so that the configured range of WWNs is used only once within the 
environment.  
The WWN range used by the Virtual Connect domain must be unique within the environment. HP provides 
a set of pre-defined ranges that are reserved for use by Virtual Connect and do not conflict with server factory 
default WWNs. 
When using the HP-defined WWN ranges, be sure that each range is used only once within the environment. 
To configure WWN address ranges, use the set domain command: 
•  VC-defined 
>set domain WwnType=VC-Defined WwnPool=5 
•  Factory default 
>set domain WwnType=Factory-Default 
Creating FC fabrics 
To create an FC SAN fabric and add it to the domain, use the add fabric command: 
>add fabric MyFabric2 Bay=3 Ports=1 Speed=2Gb 
Displaying FC fabrics 
To display a list of all FC SAN fabrics, use the show fabric command: 
>show fabric 
Serial number settings 
The serial number settings feature enables you to add a serial number and UUID to server profiles. The UUIDs 
that Virtual Connect assigns are randomly generated. A UUID pool is not required. 
By configuring VCM to assign serial numbers, a profile can present a single serial number regardless of the 
physical server. With these configuration values added to server profiles, software that is licensed to a 
particular server, based on one or both of these values, can be migrated to new server hardware without 
re-licensing the software for the new server hardware. This feature prevents you from having to reinstall serial 
number sensitive software after a system recovery. 
If you need to access the physical serial number of a server blade, the Onboard Administrator displays both 
the physical and assigned serial numbers. 
After server profile creation, the following guidelines apply: 
•  Serial numbers can be changed from factory default to VC-assigned. 
•  Factory default serial numbers cannot be changed. 
•  User-defined serial number ranges can be expanded. 
•  User-defined serial number ranges cannot be reduced. 