HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.30 User Guide
Configuring the Virtual Connect domain using the CLI  149 
remain in the "profile recovered" state until the server is powered down or removed from the enclosure. This 
feature eliminates the power cycle requirement for a server to recover. 
General requirements for adding FC or FCoE connections 
Adding FC and FCoE connections is generally allowed during profile add and edit operations. It is not 
allowed in some specific cases. Observe the following general requirements: 
•  When a profile is added, the FC/FCoE connections initially displayed are based on the FC/FCoE 
module configuration in the domain, respectively. A pair of horizontally adjacent FC/FCoE-capable 
modules has two connections. 
•  Connections can only be added or removed from the bottom. You can only add or delete connections 
at the end of the list. 
•  You can remove connections at any time (one at a time, from the bottom). 
•  If the existing profile connections do not match the current FC/FCoE module configurations, the add 
operation is not allowed. 
•  The current maximum number of FC/FCoE connections is four per I/O bay. 
The following table lists several scenarios that describe how adding FC/FCoE connections affects an existing 
profile. The scenarios are true for FC module configurations and FC modules, as well as FCoE module 
configurations and FCoE-capable modules. 
Scenario  Description 
Existing profile 
connections 
Current FC module 
configurations 
Adding profile 
connections 
1 
Start with modules in Bays 
3 and 4, create a profile, 
then edit the profile and 
add connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
—  — 
Bay 3  Bay 4 
—  — 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 3 
4  Bay 4 
Add connection, 2 times 
2 
Start with modules in Bays 
3–6, create a profile, then 
edit the profile and add 
connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
5  Bay 3 
6  Bay 4 
7  Bay 5 
8  Bay 6 
Add connection, 4 times 
3 
Start with modules in Bays 
3 and 4, create a profile, 
hotplug modules into Bays 
5 and 6, then edit the 
profile and add 
connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
Add connection, 2 times 