HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.30 User Guide
Command line  39 
Item  Description 
->show fc-connection Profile1:* 
Displays all FC SAN connections of a profile named Profile1 
->show fc-connection Profile1:1 
Displays a specific FC SAN connection of a profile named Profile1 
fcoe-connection 
Manage FCoE connections. 
Supported actions: add, help, remove, set, show 
Item  Description 
add fcoe-connection 
Add a new FCoE connection to an existing server profile. 
For more information, see "General requirements for adding FC or FCoE 
connections (on page 149)." 
Syntax 
add fcoe-connection <ProfileName> [Fabric=<FabricName>] 
[SpeedType=<1Gb|2Gb|4Gb|8Gb|Custom|Disabled>] 
[CustomSpeed=<100Mb-10Gb>] 
[WWNAddressType=<Factory-Default|User-Defined>] 
[PortWWN=<WWN address>] [NodeWWN=<WWN address>] 
[MACAddressType=<Factory-Default|User-Defined>] 
[EthernetMac=<MAC Address>]
Parameter 
ProfileName (required)
The name of an existing profile to which the new connection is added 
Properties 
Fabric (optional) 
The name of an existing fabric created on an FCoE module to associate with the 
connection. If the fabric name is not specified, the connection is marked as 
“Unassigned” and associated with a specific bay. 
SpeedType (optional) 
The requested operation speed for the server port. Valid values include "1Gb", 
"2Gb", "4Gb", "8Gb", "Custom", and "Disabled". The default value is "4Gb".
If the SpeedType is "Custom", you can configure any speed from 100Mb to 
10Gb in 100Mb increments. 
CustomSpeed (required 
if SpeedType is Custom) 
The user-defined speed for the server port. Valid values include 100Mb to 
10Gb configured in 100Mb increments. 
WWNAddressType 
(optional) 
The source of WWN address assignments to be used during the creation of the 
new connection. If not specified, the default is the domain default. If 
"User-Defined" is specified, both a Port WWN and Node WWN must also be 
specified. Valid values include "Factory-Default" and "User-Defined". 
PortWWN (required if 
WWNAddressType is 
User-Defined)
The user-defined Port WWN address to use for the connection. The PortWWN 
must be an unused WWN address. 
NodeWWN (required if 
WWNAddressType is 
User-Defined)
The user-defined Node WWN address to use for the connection. The 
NodeWWN must be an unused WWN address. 
MACAddressType 
(optional) 
The source of MAC address assignments to be used during the creation of the 
new connection. If not specified, the default is the domain default. If 
"User-Defined" is specified, EthernetMAC must also be specified. Valid values 
include "Factory-Default" and "User-Defined". 
EthernetMAC (required 
if MACAddressType is 
User-Defined)
The user-defined Ethernet MAC address to use for the connection 
Examples 