HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.30 User Guide
Command line  43 
Item  Description 
show igmp-group
Display interconnect module IGMP Group table information for the specified module. 
Syntax 
show igmp-group <ModuleID> 
Parameter 
ModuleID 
(required) 
The ID of the module for which to display the IGMP Group table. The ID is in the format 
of 
<EnclosureID>:<BayNumber>
. 
Example 
->show igmp-group enc0:1 
Displays the IGMP Group information for the module in bay 1 of enclosure enc0 
interconnect 
Manage I/O interconnect modules. 
Supported actions: add, help, remove, set, show 
Item  Description 
add interconnect 
Add an interconnect module to an imported enclosure. 
Syntax 
add interconnect <module ID> type=<moduleName> 
Parameter 
module ID(required) 
The bay identifier within an existing network in the domain. For example, bay 3 
in the local enclosure has a module ID of enc0:3. 
module (required) 
The name of the interconnect module. Use: 
•
  type=vcenet for an HP 1/10Gb VC-Enet Module 
•
  type=vcenet2 for an HP 1/10Gb-F VC-Enet Module 
•
  type=vcenet3 for an HP VC Flex-10 Enet Module 
•
  type=vcenet5 for an HP FlexFabric 10Gb/24-port Module 
•
  type=vcfc for an HP 4Gb VC-FC Module 
•
  type=vcfc2 for an HP VC 8Gb 24-Port FC Module 
•
type=vcfc3
 for an HP VC 8Gb 20-Port FC Module 
Example 
->add interconnect enc0:3 module=vcenet5 
Adds an HP VC FlexFabric 10Gb/24-port Module to bay 3 of enclosure enc0 
Item  Description 
remove interconnect 
Remove an interconnect module from the domain. Normally, this command is 
used if a module has been physically removed from the enclosure. To be 
removed, the module must not be currently in use by any element in the domain.
Syntax 
remove interconnect <ModuleID|*> 
Parameter 
ModuleID(required) 
The ID of the module to remove. The ID format is 
<EnclosureID>:<BayNumber>. Use <EnclosureID:*> to remove all 
interconnect modules that are physically present in the enclosure from the 
domain. Use <*:BayNumber> to remove all interconnect modules in the 
specified bay that are not physically present in any enclosures from the domain. 
Use "*" to remove all interconnect modules that are not physically present in any 
enclosure from the domain. 
To display a list of the IDs corresponding to modules in the domain, use the 
show 
interconnect
 command. 