HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.51/3.60 User Guide
Configuring the Virtual Connect domain using the CLI  146 
6 
Start with modules in Bays 
3–6, create a profile (add 
4 connections), hotplug 
modules into Bays 7 and 
8, then edit the profile. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
5  Bay 3 
6  Bay 4 
7  Bay 5 
8  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
Bay 7  Bay 8 
Add connection is 
disallowed because the 
current FC module 
configurations do not 
match the existing 
connections in the 
profile. 
This profile is not useful 
after the hotplug. To 
resolve this issue, delete 
connections 5–8, save 
the profile, and then 
scenario 5 applies. 
7 
Start with modules in Bays 
5 and 6, create a profile, 
hotplug modules into Bays 
3 and 4, then edit the 
profile. 
Port  Connected to 
1  Bay 5 
2  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Add connection is 
disallowed because the 
current FC module 
configurations do not 
match the existing 
connections in the 
profile. 
8 
Start with modules in Bays 
5–8, create a profile, 
hotplug modules into Bays 
3 and 4, then edit the 
profile. 
Port  Connected to 
1  Bay 5 
2  Bay 6 
4  Bay 7 
5  Bay 8 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
Bay 7  Bay 8 
Add connection is 
disallowed because the 
current FC module 
configurations do not 
match the existing 
connections in the 
profile. 
9 
Start with FCoE-capable 
modules in Bays 1 and 2, 
then create a profile and 
add connections. 
Port  Connected to 
1  Bay 1 
2  Bay 2 
Bay 1  Bay 2 
—  — 
—  — 
—  — 
Port  Connected to 
1  Bay 1 
2  Bay 2 
3  Bay 1 
4  Bay 2 
5  Bay 1 
6  Bay 2 
7  Bay 1 
8  Bay 2 
Add connection, 6 times 