HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.51/3.60 User Guide
Introduction  7 
servers. Virtual Connect cleanly separates server enclosure administration from LAN and SAN 
administration. 
VCM is embedded on the VC-Enet module. You can access VCM through a web-based GUI or CLI. The 
Onboard Administrator provides a web link to the Virtual Connect GUI. 
The VC modules support the HP BladeSystem c7000 Enclosure, the HP BladeSystem c3000 Enclosure, and 
all the server blades and networks contained within the enclosure. FlexFabric modules are only supported in 
BladeSystem c7000 enclosures and G6 or newer server blades with Virtual Connect firmware v3.15 and 
later. 
VC-Enet modules enable connectivity to all brands of data center Ethernet switches. VC-Enet modules can 
also be directly connected to other types of devices, such as printers, laptops, rack servers, and network 
storage devices. 
The VC-FC and FlexFabric modules enable connectivity of the enclosure to Brocade, Cisco, McDATA, or 
QLogic data center FC switches. Every FC fabric is limited in the number of switches it can support, but the 
VC-FC modules do not appear as switches to the FC fabric and do not count against FC fabric limits. 
A basic Virtual Connect domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 16 
servers (or up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem c3000 
Enclosure for a total of 8 servers (or up to 16 servers if the double-dense option is enabled). For more 
information on the double-dense option, see "Double-dense server bay option" in the user guide. Within the 
domain, any server blade with the requisite LAN or SAN devices can access any LAN or SAN connected to 
a VC module, and a server blade of a given processor type (Integrity or X86) can be used as a spare for any 
server blade of the same processor type within the same enclosure, as long as the server has the requisite 
number and type of connections. Using network access groups feature, the network administrator can clearly 
define a separation of networks based on their allowed functionality and prevent the server administrator 
from assigning specific network combinations in the same server profile. 
By stacking (cabling) the VC-Enet modules together within the domain and connecting the VC-FC or 
FlexFabric module FC uplinks on the same bay of all enclosures to the same FC switch, every server blade in 
the domain can be configured to access any external network or fabric connection. With this configuration, 
you can use VCM to deploy and migrate a server blade profile to any server in the Virtual Connect domain 
without changing external LAN or SAN configurations. 
Using multiple enclosures 
Multiple enclosure support enables up to four c7000 enclosures to be managed within a single Virtual 
Connect domain for a total of 128 servers, if double-dense support is enabled while using the Domain Setup 
Wizard. There are 16 half-height or 8 full-height server bays in a c7000 enclosure. A combination of 
full-height and half-height servers can be used in the same enclosure. 
Multiple enclosure domains are not supported on c3000 enclosures. The VC-Enet or FlexFabric modules use 
stacking cables between enclosures so that network traffic can be routed from any server Ethernet port to any 
uplink within the VC domain. Since FC does not support stacking, the VC-FC or FlexFabric module FC uplinks 
on the same bay of all enclosures must be connected to the same FC switch to enable profile mobility. 
The management interfaces for all enclosure Onboard Administrators and VC modules within the same VC 
domain must be on the same lightly loaded subnet and highly reliable network. Overloads or loss of 
connectivity can disable configuration attempts until the connectivity is re-established and synchronized with 
the domain. The Onboard Administrator IP addresses used must be configured to be static. The Onboard 
Administrator user credential for all enclosures must be consistent to enable VCSU firmware updates for VC 
modules in the remote enclosures. All FC-capable modules in the same horizontally adjacent bay pair (bays 
1-2, 3-4, and so on) must be of the same type and position in all enclosures. 