HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.51/3.60 User Guide
Command line  92 
Item  Description 
Port (optional) 
The server TCP port number. Valid values include a valid port number between 1 
and 65535. The default port number is 49. 
ServerKey (optional) 
The plain-text string used to encrypt user details exchanged with the primary 
TACACS server. It must match the server key configured for this VC on the 
primary server. TACACS authentication will not work if the server key is blank or 
null. 
Timeout (optional) 
The time in seconds by which a server response must be received before a new 
request is made. The valid range of values is from 1 to 600 seconds. The default 
timeout is 10 seconds. 
SecondaryServer 
Address (optional) 
The IP address or host name of the secondary TACACS server used for 
authentication 
SecondaryPort 
(optional)
The TCP port to use for TACACS communication. Valid values include a valid port 
number between 1 and 65535. The default TCP port number is 49. 
SecondaryServerKey 
(optional) 
The plain-text string used to encrypt user details exchanged with the secondary 
TACACS server. It must match the server key configured for this VC on the 
secondary server. TACACS authentication will not work if the server key is blank 
or null. 
SecondaryTimeout 
(optional) 
The timeout value in seconds for TACACS communication with the secondary 
server 
LoggingEnabled 
(optional)
Enables or disables command logging on the TACACS+ server. Valid values 
include "true" and "false". 
Examples 
->set tacacs -test Enabled=true ServerAddress=192.168.0.27 
Tests the TACACS+ configuration changes without applying them 
->set tacacs Enabled=true ServerAddress=192.168.0.124 
ServerKey=test123 SecondaryServerAddress=tacserver.hp.com 
SecondaryServerKey=test456 
Enables TACACS+ authentication for users 
->set tacacs LoggingEnabled=true 
Enables TACACS server logging 
Item  Description 
show tacacs
Display the Virtual Connect TACACS+ authentication settings. 
Syntax 
show tacacs 
Example 
->show tacacs 
Displays TACACS+ information 
uplinkport 
Manage interconnect module uplink ports. 
Supported actions: add, help, remove, set, show 
Item  Description 
add uplinkport
Add a new uplink port to an existing network or a shared uplink port set. 
Syntax 
add uplinkport <PortID> [Network=<NetworkName> | 
UplinkSet=<UplinkSetName>] 
[Speed=<Auto|10Mb|100Mb|1Gb|10Gb|Disabled>] 
[Role=<Primary|Secondary>]