HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.70/3.75 User Guide
Configuring the Virtual Connect domain using the CLI  151 
Adding a network access group to a profile 
To create a new profile and assign an existing network access group, use the add profile command: 
>add profile MyNewProfile2 Nag=DatabaseNetGroup 
To modify the network access group of an existing server profile, use the set profile command: 
>set profile Profile1 Nag=NetGroup1 
Assigning a server profile to a device bay 
To assign a server profile to a specific device bay, use the assign profile command: 
>assign profile MyProfile enc0:1 
When defining server profiles in a multi-enclosure configuration, profiles can be assigned to server bays in 
any of the enclosures that have been added and imported into the domain. 
When a profile is created and assigned to a multi-blade server, the profile is applied to all of the blades in 
the multi-blade server. Be sure that the profile contains enough Ethernet and Fibre Channel connection entries 
for all of the ports on all of the blades in the multi-blade server. 
Configuring IGMP settings 
To configure Ethernet IGMP snooping settings, use the set igmp command: 
>set igmp Enabled=true Timeout=30 
The IGMP Snooping feature enables VC-Enet modules to monitor (snoop) the IGMP IP multicast membership 
activities and configure hardware Layer 2 switching behavior of multicast traffic to optimize network 
resource usage. IGMP v1, v2, and v3 snooping are supported. 
The IGMP Snooping idle timeout interval is set to 260 seconds by default. This value is the "Group 
Membership Interval" value as specified by IGMP v2 specification (RFC2236). For optimum network 
resource usage, set the interval to match the configuration on the customer network's multicast router settings. 
By default, unregistered IGMP multicast traffic traversing VC–Enet modules is flooded on the configured 
Ethernet network. To prevent flooding, set the NoFlood property to true. 
>set igmp Enabled=true NoFlood=true 
Unregistered multicast traffic from uplinks is dropped and traffic from the server ports is redirected to the 
active uplink port. IGMP Snooping must be enabled to modify this setting. 
Configuring MAC cache failover settings 
•  To configure MAC Cache Failover settings, use the set mac-cache command: 
>set mac-cache enabled=true refresh=10 
•  To display MAC Cache Failover settings, use the show mac-cache command: 
>show mac-cache 
When a VC-Enet uplink that was previously in standby mode becomes active, external Ethernet switches can 
take several minutes to recognize that the c-Class server blades can now be reached on this newly active 
connection. Enabling Fast MAC Cache Failover causes Virtual Connect to transmit Ethernet packets on newly 
active links, which enables the external Ethernet switches to identify the new connection and update their 
MAC caches appropriately. This transmission sequence repeats a few times at the MAC refresh interval (HP 
recommends 5 seconds) and completes in about 1 minute. 