HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.70/3.75 User Guide
Command line  97 
Item  Description 
show statistics- 
throughput
Display throughput information for the specified physical port, FlexNIC, and the 
aggregated throughput information for the specified LAG. 
Syntax 
show statistics-throughput <config|PortID> 
[LAGID=<encXX:BayNumber:lagNN>]
Parameters 
PortID (optional) 
The port ID of the port/subport for which to display throughput information. PortID is 
composed of 
<EnclosureID>:<BayNumber>:<PortLabel>[:<SubportLabel>]. Port 
throughput collection must be enabled for the domain by issuing the set 
statistics-throughput command. A column that contains an "R" indicates that 
the statistics were reset by the user during that time period, therefore the throughput is 
not available for that time period. 
config (required 
if PortID is not 
specified)
Displays the current configuration of throughput statistics 
Property 
LAGID (optional) 
The LAG ID on which to display throughput information. The LAG ID must be in the 
format <EnclosureID>:<BayNumber>:<LagLabel>. LagLabel must be in the 
format lagNN, where NN is the LAG number. 
A listing of the possible uplink port IDs can be obtained by using the show 
uplinkport
 command. 
Examples 
->show statistics-throughput enc0:1:X1 
Displays the port throughput statistics for port X1 of the module in bay1 of enclosure 
enc0 
->show statistics-throughput enc0:1:d1:v1 
Displays the subport throughput statistics for subport v1 of port d1 from the module in 
bay1 of enclosure enc0 
->show statistics-throughput config 
Displays the current configuration of the throughput statistics 
->show statistics-throughput LAGID=enc0:1:lag25 
Displays the aggregated throughput statistics based on the LAGID 25 for the module in 
bay1 of enclosure enc0 
Item  Description 
set statistics- 
throughput
Enable or disable the port throughput statistics and set the sample rate. 
Syntax 
set statistics-throughput <Enabled=[true|false]> 
[SampleRate=<1m|2m|3m|4m|5m|1h>]>
Parameters 
Enabled 
(optional) 
Enables or disables port throughput statistics. Valid values include "true" and "false". 
SampleRate 
(optional) 
Configures the sample rate for statistics collection. Valid values include: 
•
  Use SampleRate=1m for 1 minute samples, collecting up to 5 hours of samples. 
•
  Use SampleRate=2m for 2 minutes samples, collecting up to 10 hours of samples. 
•
  Use SampleRate=3m for 3 minutes samples, collecting up to 15 hours of samples. 
•
  Use SampleRate=4m for 4 minutes samples, collecting up to 20 hours of samples. 
•
  Use SampleRate=5m for 5 minutes samples, collecting up to 25 hours of samples. 
• 
Use 
SampleRate=1h
 for 60 minutes samples, collecting up to 12.5 days of 