HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.01 User Guide
Introduction  10 
Command  Changes  Virtual Connect 3.70  Virtual Connect 4.01 
add user 
set user 
show user 
Modified these 
commands to replace 
the "Privileges" 
property with "Roles" 
add user <UserName> 
Password= 
<password> 
[FullName= <Full 
Name>] 
[ContactInfo= 
<Contact Details>] 
[Enabled=<True| 
False>] 
[Privileges 
=<Storage| 
Network|Server| 
Domain|*>]
add user <UserName> 
Password= 
<password> 
[FullName= <Full 
Name>] 
[ContactInfo= 
<Contact Details>] 
[Enabled=<True| 
False>] [Roles 
=<Storage| 
Network|Server| 
Domain|*>] 
add radius-group 
set radius-group 
show radius-group 
Modified these 
commands to replace 
the "Privileges" 
property with "Roles" 
add radius-group 
<GroupName> 
[Description= 
<string>] 
[Privileges 
=<privileges>]
add radius-group 
<GroupName> 
[Description= 
<string>][Roles 
=<roles>] 
add ldap-group 
show ldap-group 
set ldap-group 
Modified these 
commands to replace 
the "Privileges" 
property with "Roles" 
add ldap-group 
<GroupName> 
[Description= 
<string>] 
[Privileges 
=domain,server, 
network, storage]
add ldap-group 
<GroupName> 
[Description= 
<string>] [Roles 
=domain,server, 
network,storage] 
add mfs-filter 
remove mfs-filter 
The new managed 
element manages 
Multicast Filters in 
Multicast Filtersets. 
Not supported  All of these commands are 
supported. 
add mcast-filter 
remove mcast-filter 
set mcast-filter 
show mcast-filter 
The new managed 
element monitors and 
manages multicast 
group membership for 
hosts subscribing to 
IGMP multicast traffic. 
Not supported  All of these commands are 
supported. 
add mcast-filter-rule 
remove 
mcast-filter-rule 
The new managed 
element manages new 
Multicast Filter rules for 
a Multicast filter. 
Not supported  All of these commands are 
supported. 
add mcast-filter-set 
remove 
mcast-filter-set 
set mcast-filter-set 
show mcast-filter-set
The new managed 
element manages 
Multicast Filtersets. 
Not supported  All of these commands are 
supported. 
show interconnect-mac-
table 
Modified this command 
to update the Port field 
output 
The Port field displayed 
Flex-10 downlink ports 
as 
d1:a, d1:b, d1:c, 
d1:d.
The Port field displays 
Flex-10 downlink ports as 
d1:v1, d1:v2, 
d1:v3, d1:v4.
Virtual Connect overview 
HP Virtual Connect is a set of interconnect modules and embedded software for HP BladeSystem c-Class 
enclosures that simplifies the setup and administration of server connections. Virtual Connect includes the 
following components: 
•  VC-Enet modules 