HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.01 User Guide
Command line  79 
Item  Description 
PrefSpeed (required if 
PrefSpeedType is "Custom") 
The connection speed for any Ethernet connection attached to these 
networks. Valid values range from 100Mb to 10Gb in 100Mb 
increments. 
MaxSpeedType (Optional) 
The 
maximum connection speed for any Ethernet connection attached to 
these networks. Valid values include "Unrestricted" and "Custom". 
"Custom" enables you to configure the preferred speed. The default value 
is "Unrestricted". 
MaxSpeed (required if 
MaxSpeedType is "Custom") 
The maximum connection speed for any Ethernet connection attached to 
these networks. Valid values range from 100Mb to 10Gb in 100Mb 
increments. 
Nags (optional) 
The network access groups to which the networks belong, separated by 
commas. D
o not use spaces unless they are enclosed in quotation marks. 
If nags is not specified, the network access groups are not changed. 
SmartLink (optional) 
Enables or disables the SmartLink capability for the networks. Valid values 
include "Enabled" and "Disabled". 
Labels (optional) 
Labels assigned to these networks. Labels are used in the GUI to help with 
management of large numbers of networks. Labels can be assigned in the 
CLI, but are only used in the GUI. A maximum of 16 labels can be 
assigned. 
Color (optional) 
Color assigned to these networks. Color is used in the GUI to help with 
management of large numbers of networks. A color can be assigned in 
the CLI, but is only used in the GUI. Allowed colors are red, green, blue, 
purple, or orange. 
Example 
->set network-range UplinkSet=Alpha 
VLANIDs=1-10,21-30 SmartLink=Enabled 
Changes the SmartLink setting for multiple networks 
port-monitor 
Manage port monitor configuration. 
Supported actions: help, add, remove, set, show 
Item  Description 
add port monitor
Add a new network analyzer port and other ports to be monitored. 
Syntax 
add port-monitor [AnalyzerPort=<PortID>] 
[Speed=<Auto|10Mb|100Mb|1Gb|10Gb|Disabled>] 
 [Duplex=<Auto|Half|Full>] [MonitorPort=<PortID>] 
 [Direction=<ToServer|FromServer|Both>] 
Properties 
AnalyzerPort 
(optional) 
The uplink port that is used for monitoring network traffic. Only one port can be 
configured as the analyzer port. After a port is allocated to port monitoring, it is not 
available for use in 
VC networks and shared uplink sets. The format of the network 
analyzer port is <EnclosureID>:<InterconnectBay>:<PortNumber>. 
If the EnclosureID is not specified, the default enclosure is the local enclosure where 
the domain resides. 
Speed (optional) 
The port speed for the network analyzer port. Valid values include "Auto", 
"10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". The default value is "Auto".
If there is no connector present on the analyzer port, only "Auto" and "Disabled" 