HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.20 User Guide
Introduction  10 
# Add uplink ports to the networks 
add uplinkport enc0:1:1 network=MyNetwork 
add uplinkport enc0:1:2 network=Network2 
# Create a Shared Uplink Port Set 
add uplinkset SharedSet1 
# Add a new FCoE SAN fabric connection to a profile 
add fcoe-connection MyNewProfile Fabric=SAN_5 
# Reset the active QoS configuration type to the factory default settings but 
does not change the saved configuration types 
reset qos -active 
# Set the domain default LACP timer to the short setting (one second) 
set lacp-timer default=Short 
# Add a Multicast Filter "filter1" to Filterset "mfs1" 
add mfs-filter FilterSet=mfs1 McastFilter =filter1 
# Set the global option to enable the loop protection and pause flood protection 
set port-protect networkLoop=Enabled PauseFlood=Enabled 
# Set idle user sessions to expire after 20 minutes of inactivity 
set session Timeout=20 
# Create a new Multicast Filter and adds it to the domain 
add mcast-filter MyMcastFilter 
# Assign a profile to a device bay 
assign profile MyProfile enc0:1 
# Done!!! 
Virtual Connect overview 
HP Virtual Connect is a set of interconnect modules and embedded software for HP BladeSystem c-Class 
enclosures. VC simplifies the setup and administration of server connections and includes the following 
components: 