HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.20 User Guide
Command line  112 
Item  Description 
<EnclosureID>:<InterconnectBay>[:<PortNumber1[-PortNumberN]>]. 
The ID for the poll port can be referenced from the output of the show 
sflow-ports
 command. 
PollingIntervals 
(optional) 
Specifies the polling interval which is the maximum number of seconds between 
successive samples of the counters associated with these ports. Each value in the 
list of polling interval has a corresponding port in the PollPorts list. The valid 
polling interval range is from 1 to 65535 seconds. The default value is "10 
seconds". Disable polling on a port using the remove sflow-ports 
command. 
Configure the module network using the set sflow-module command before 
adding the module port for sampling or polling to a receiver. 
Examples 
->set sflow-ports Alpha SamplePorts=enc0:1:d1 
Samplingrates=2048 Direction=Both PollPorts=enc0:1:d4 
PollingIntervals=10 
Modifies sample and polling ports 
Item  Description 
show sflow-ports 
Display the port to be sampled or polled for a receiver. 
Syntax 
show sflow-ports [<ReceiverName|*>] 
Parameter 
ReceiverName 
(optional) 
The name of an existing sflow receiver in the domain. A receiver name of "*"' 
displays ports of all the receivers. 
Examples 
->show sflow-ports 
Displays the sflow sample and polling ports 
->show sflow-ports Alpha 
Displays the Alpha sflow port 
sflow-receiver 
Configure the receivers. 
Supported actions: add, help, remove, set, show 
Item  Description 
add sflow-receiver
Add a receiver. 
Syntax 
add sflow-receiver <ReceiverName> 
IpAddress=<IPAddress>[Port= <1-65535>] 
[MaxHeaderSize=<128|256|512|1024>] 
[MaxDatagramSize=<256-1500>]
Parameter 
ReceiverName 
(required) 
Specifies the unique name of the receiver. A valid receiver name can have a 
minimum of one character and maximum of 64 characters. Only alphanumeric 
characters, -(hyphen), and _(underscore) are allowed. White spaces are not 
allowed. 
Properties 
IpAddress (required)
Specifies the IP Address of the receiver where the sflow datagrams are sent 
Port (optional) 
Specifies the UDP port number of the receiver where the sflow datagrams are 
sent. The valid range is from 1 to 65535. The default value is "6343". 