HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.20 User Guide
Command line  115 
snmp-trap 
Manage SNMP trap information. 
Supported actions: add, help, remove, set, show, test 
Item  Description 
add snmp-trap 
Adds a new SNMP trap destination. 
You can configure up to five VC-Enet and five VC-FC SNMP trap destinations. 
Avoid using duplicate trap destinations. Setting duplicate trap destinations can 
result in duplicate traps being sent to the same destination, or only one of the trap 
destinations being configured. 
Syntax 
add snmp-trap <Name> Address=<IPAddress|DNSname> 
[Community=<community name 
string>][Format=<SNMPv1|SNMPv2>][Severity=<trap 
severity|All|None>][DomainCategories=<domain trap 
category|All|None>][EnetCategories=<enet trap 
category|All|None>][FcCategories=<fc trap 
category|All|None>]
Parameter 
Name (required)
A unique name for the new trap being added 
Properties 
Address (required)
IP address or DNS name for the trap destination 
Community (optional) 
The SNMP community name string for the specified trap. If not specified, the default 
value is "public". For VC-Enet modules, the maximum string length is 39. For VC-FC 
modules, the maximum string length is 24. 
Format 
Format of the new trap. Values are "SNMPv1" and "SNMPv2". If not specified, the 
default is "SNMPv1". 
Severities 
Trap severities to send to the destination. Values are "Normal", "Unknown", "Info", 
"Warning", "Minor", "Major", "Critical", "All", and "None". Multiple severities 
can be specified, separated by commas. The default severity is "None". 
DomainCategories 
The VC domain trap categories to send to the destination. Values are "Legacy", 
"DomainStatus", "NetworkStatus", "FabricStatus", "ProfileStatus", "ServerStatus", 
"EnetStatus", FcStatus", "All", and "None". Multiple categories can be specified, 
separated by commas. 
EnetCategories 
The VC Ethernet trap categories to send to the destination. Values are "PortStatus", 
"PortThreshold", "Other", "All", and "None". Multiple categories can be specified, 
separated by commas. 
FcCategories 
The VC Fibre Channel trap categories to send to the destination. Values are 
"PortStatus", "Other", "All", and "None". Multiple categories can be specified, 
separated by commas. 
Examples 
->add snmp-trap EnetManagementStation Address=192.112.34.10 
Community=private Format=SNMPv1 Severity=Normal,Critical 
EnetCategories=Other 
Adds a new trap destination for VC-Enet modules 
->add snmp-trap FcManagementStation Address=192.112.72.3 
Community=private Format=SNMPv1 FcCategories=Other 
Adds a new trap destination for VC-FC modules 
->add snmp-trap MyTrap Address=192.112.66.12 
Adds a new trap using typical defaults 
->add snmp-trap MyTrap Address=2001:05c0:9168::1 
Severity=All EnetCategories=All 
Adds a new trap destination using an IPv6 address 