HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.20 User Guide
Configuring the Virtual Connect domain using the CLI  192 
2 
Start with modules in Bays 
3–6, create a profile, then 
edit the profile and add 
connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
5  Bay 3 
6  Bay 4 
7  Bay 5 
8  Bay 6 
Add connection, 4 times 
3 
Start with modules in Bays 3 
and 4, create a profile, 
install modules into Bays 5 
and 6, then edit the profile 
and add connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
Add connection, 2 times 
4 
Start with modules in Bays 3 
and 4, create a profile (add 
2 connections), install 
modules into Bays 5 and 6, 
then edit the profile. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 3 
4  Bay 4 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Add connection is disallowed 
because the current FC module 
configurations do not match 
the existing connections in the 
profile. 
This profile is not useful after 
the hot-plug install. To resolve 
this issue, delete connections 3 
and 4, save the profile, and 
then scenario 3 applies. 
5 
Start with modules in Bays 
3–6, create a profile, install 
modules into Bays 7 and 8, 
then edit the profile and add 
connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
Bay 7  Bay 8 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
5  Bay 7 
6  Bay 8 
Add connection, 2 times 
6 
Start with modules in Bays 
3–6, create a profile (add 4 
connections), install modules 
into Bays 7 and 8, then edit 
the profile. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
5  Bay 3 
6  Bay 4 
7  Bay 5 
8  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
Bay 7  Bay 8 
Add connection is disallowed 
because the current FC module 
configurations do not match 
the existing connections in the 
profile. 
This profile is not useful after 
the hot-plug install. To resolve 
this issue, delete connections 
5–8, save the profile, and then 
scenario 5 applies. 
7 
Start with modules in Bays 5 
and 6, create a profile, 
install modules into Bays 3 
and 4, then edit the profile. 
Port  Connected to 
1  Bay 5 
2  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Add connection is disallowed 
because the current FC module 
configurations do not match 
the existing connections in the 
profile. 
To make this profile useful, 
remove the two connections, 
save the profile, and then 
begin adding connections. 