HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.20 User Guide
Configuring the Virtual Connect domain using the CLI  196 
Connect Ethernet module. This feature can be useful when troubleshooting the Virtual Connect Manager. The 
network and FC processing of the Virtual Connect subsystem is not disturbed during the restart or failover of 
the Virtual Connect Manager. 
If the command line option -failover is included in the reset vcm command and a backup Virtual 
Connect Ethernet module is available, the command line displays the following message: 
SUCCESS: The Virtual Connect Manager is being reset. Please wait... 
You are logged out of the session after approximately 1 minute. An attempted login to the same Virtual 
Connect Ethernet module is rejected with the following message: 
Virtual Connect Manager not found at this IP address. 
If you attempt to log in to the backup module, you might receive the following error message: 
Unable to communicate with the Virtual Connect Manager. Please retry again 
later. 
The login should succeed after the Virtual Connect Manager restarts on the backup Virtual Connect Ethernet 
module. Allow up to 5 minutes, depending on the enclosure configuration. 
If the command line option -failover is not included in the reset vcm command or a backup Virtual 
Connect Ethernet module is not available, the command line displays the following message: 
SUCCESS: The Virtual Connect Manager is being reset. Please wait... 
You are logged out of the session after approximately 1 minute. If you attempt to log in to the module again, 
you might receive the following error message: 
Unable to communicate with the Virtual Connect Manager. Please retry again 
later. 
The login should succeed after the Virtual Connect Manager restarts. Allow up to 5 minutes, depending on 
the enclosure configuration. 