HP Virtual Connect Manager Command Line Interface Version 2.10 User Guide
Command line  30 
Item Description 
->add fc-connection MyNewProfile AddressType=User-
Defined PortWWN=50:06:0B:00:00:C2:62:00 
NodeWWN=50:06:0B:00:00:c2:62:01 
Adds a new FC SAN connection and provides user-defined WWN addresses
Item Description 
remove fc-connection 
Remove the last FC connection from an existing server profile. 
Syntax 
remove fc-connection <ProfileName> 
Parameter 
ProfileName (required) 
The name of an existing profile from which the last FC connection is to be 
removed. 
Example 
->remove fc-connection MyProfile 
Removes an FC connection from a profile 
Item Description 
set fc-connection 
Modify an existing server profile connection. 
Syntax 
set fc-connection <ProfileName> <Port> 
[Fabric=<FabricName>] 
[Speed=<Auto|1Gb|2Gb|4Gb|8Gb|Disabled>] 
[BootPriority=<priority>] [BootPort=<portName>] 
[BootLun=<LUN>] 
Parameters   
ProfileName (required) 
The name of the server profile that contains the connection to modify 
Port (required) 
The port number of the connection being modified 
Properties 
Fabric (optional) 
The name of the FC SAN fabric to associate with the connection. The fabric 
being specified should be associated with the same bay as the FC 
connection. 
Speed (optional) 
The port speed of the FC SAN connection. Valid values include "Auto", 
"8Gb", "4Gb", "2Gb", "1Gb", and "Disabled". 
Speed restrictions: 
For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module, 
valid speed values include "Auto","1Gb","2Gb", and "4Gb", and 
"Disabled". 
BootPriority 
(optional) 
Controls whether the FC HBA port is enabled for SAN boot and affects the 
BIOS boot order. Valid values include "BIOS", "Primary", "Secondary", and 
"Disabled". 
BootPort (optional) 
The target WWPN of the controller interface on the Fibre Channel storage 
target. The port name is a 64-bit identifier in the format: 
NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number 
BootLun (optional) 
The LUN of the volume used for SAN boot. Valid values include an integer 
from 0-255 or 16 hex digits (HP-UX only). 
Examples 
->set fc-connection MyProfile 1 Fabric=SAN_5 
Changes the fabric of an FC SAN fabric connection 