HP Virtual Connect Manager Command Line Interface Version 2.10 User Guide
Command line  56 
Item Description 
->show snmp Enet 
Displays SNMP configuration for only VC-Enet modules 
->show snmp FC 
Displays SNMP configuration for only VC-FC modules
->show snmp 
Displays SNMP configuration for all VC modules 
snmp-trap 
Displays SNMP trap information 
Supported actions: add, remove, set, show 
Item Description 
snmp-trap 
Add a new SNMP trap destination for VC-Enet and VC-FC interconnect modules. 
Syntax 
add snmp-trap <TrapID> [Community=<community name string>] 
Parameter   
TrapID (required) 
(Required) The reference name of the new trap destination to be added. The 
format of the trap ID is <ENET|FC>:<Address> where the address is the IP 
address of the trap destination host. 
Property   
Community 
(optional) 
The SNMP community name string for the specified trap.Default is "public". For 
VC-ENET modules, maximum string length is 39. For VC-FC modules, maximum 
string length is 24. 
Examples 
->add snmp-trap ENET:192.112.34.89 community=datacenter1 
Adds a new trap destination for VC-Enet modules 
->add snmp-trap FC:192.112.34.89 community=public 
Adds a new trap destination for VC-FC modules 
Item Description 
remove snmp-trap 
Remove a previously configured SNMP trap destination. 
Syntax 
remove snmp-trap <TrapID | *> 
Parameter   
TrapID (required) 
(Required) The reference name of the trap destination to be removed. The format 
of the trap ID is <ENET|FC>:<Address> where the address is the IP address of 
the trap destination host. "*" removes all the configured SNMP traps. 
Example 
->remove snmp-trap ENET:192.135.67.89 
Removes an SNMP trap destination for VC-Enet modules 
Item Description 
set snmp-trap 
Modify SNMP trap configuration properties. 
Syntax 
set snmp-trap <TrapID> Community=<community name string> 