HP Virtual Connect Manager Command Line Interface Version 2.10 User Guide
Introduction 6 
The Virtual Connect FC modules enable connection of the enclosure to Brocade, Cisco, McData, or 
Qlogic data center Fibre Channel switches, but the modules do not appear as switches to the Fibre 
Channel fabric. 
A basic Virtual Connect domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 
16 servers (or up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem 
c3000 Enclosure for a total of eight servers (or up to 16 servers if the double-dense option is enabled). 
Within the domain, any server blade can access any LAN or SAN connected to a VC module, and a 
server blade can be used as a spare for any server blade within the same enclosure. 
By stacking (cabling) the Ethernet modules within the domain and connecting the FC modules to the same 
set of FC SANs, every server blade in the domain can be configured to access any external network 
connection. With this configuration, the administrator can use Virtual Connect Manager to deploy and 
migrate a server blade profile to any server in the Virtual Connect domain without changing external LAN 
or SAN configurations. 
Using multiple enclosures 
Multiple enclosure support enables up to four c7000 enclosures to be managed within a single Virtual 
Connect domain for a total of 128 servers, if double-dense support is enabled. Multiple enclosure 
domains are not supported on c3000 enclosures. The VC-Enet modules use stacking cables between 
enclosures so that network traffic can be routed from any server Ethernet port to any uplink within the VC 
domain. 
By stacking (cabling) the Ethernet modules within the domain, every server blade in the domain can be 
configured to access any external network connection. Fibre Channel modules within different enclosures 
are each connected directly to the same set of FC SANs. With this configuration, the administrator can 
use Virtual Connect Manager to deploy and migrate a server blade profile to any server in the Virtual 
Connect domain without changing external LAN or SAN configurations. 
Using multiple c7000 enclosures, you can install up to 16 VC-Enet modules and up to 16 VC-FC modules 
in the same domain, with a maximum of 8 VC-Enet or 4 VC-FC modules per enclosure. 
The management interfaces for all enclosure OAs and VC modules within the same VC domain must be 
on the same lightly loaded subnet. The OA IP addresses used must be configured to be static. 
Command line overview 
The HP Virtual Connect Manager Command Line Interface can be used as an alternative method for 
managing the Virtual Connect Manager. Using the CLI can be useful in the following scenarios: 
•  HP Management Applications (for example, Systems Insight Manager or Insight Control tools) can 
query the Virtual Connect Manager for information these tools need to present a complete 
management view of HP BladeSystem enclosures and devices. This interface is also used by the 
Management tools to execute provisioning and configuration tasks to devices within the enclosure. 
•  Users can develop tools that utilize Virtual Connect Manager functions for data collection and for 
executing provisioning and configuration tasks. 
•  When no browser is available or you prefer to use a command line interface, you can access 
management data and perform configuration tasks. 