HP Virtual Connect Manager Command Line Interface Version 2.10 User Guide
Configuring the Virtual Connect domain using the CLI  80 
Creating an enet-network 
To create a new Ethernet network use the add network command: 
>add network MyNetworkName 
Modifying enet-network properties 
To modify Ethernet network properties, use the set network command: 
>set network MyNetworkName state=enabled name=NewName smartlink=enabled 
Displaying enet-networks 
To display Ethernet network properties, use the show network command: 
•  Summary display 
>show network 
•  Detailed display 
>show network * 
•  Single network display 
> show network MyNetwork 
Adding uplink ports to an enet-network 
To add uplink ports to an existing Ethernet network, use the add uplinkport command: 
>add uplinkport enc0:1:1 network=MyNetwork 
>add uplinkport 1:1 network=MyNetwork 
Modifying uplink port properties 
To modify an uplink port that exists as a member of a network or shared uplink set, use the set 
uplinkport command: 
>set uplinkport network=Network1 speed=1Gb 
Creating a shared uplink port set 
To create a shared uplink port set, use the add uplinkset command: 
>add uplinkset MyUplinkSetName 
A shared uplink set is a way of identifying HP 1/10Gb VC-Enet module uplinks that will carry multiple 
networks over the same cable. In this case, each Ethernet packet carries a VLAN tag (IEEE 802.1Q) to 
identify the specific network to which it belongs. On shared uplinks, the VLAN tags are added when 
packets leave the VC-enabled enclosure and are removed when packets enter the enclosure. The external 
Ethernet switch and the Virtual Connect Manager must be configured to use the same VLAN tag identifier 
(a number between 1 and 4094) for each network on the shared uplink(s). 
Virtual Connect places no special restrictions on which VLAN identifiers can be used, so the VLAN IDs 
already used for the networks in the data center can be used on these shared uplinks. To configure a 
shared uplink set for VLAN tagging, obtain a list of the network names and their VLAN IDs. 
A shared uplink set enables multiple ports to be included to support port aggregation and link failover 
with a consistent set of VLAN tags. 