HP Virtual Connect Version 2.31Release Notes
Hardware and firmware requirements  7 
Product  Minimum firmware version 
NC382m 
Boot code version 4.4.14 and MBA version 
4.4.16 or higher 
NC370i, NC373i, and 
NC373m 
Boot code version 1.9.6 and C Class option 
ROM 1.1.3* or higher. 
To use NC373m with the BL680c G5 server 
blade, the option ROM must be updated to 
NC373m Boot code version 1.9.6 and C Class 
option ROM 1.2.7 or higher. 
NC326i, NC325m, and 
NC326m 
Boot code version 3.28 and C Class option 
ROM 1.1.3* or higher. 
To use NC325m with the BL680c G5 server 
blade, the option ROM must be updated to 
NC325m Boot code version 3.28 and C Class 
option ROM 1.2.8 or higher. 
To use NC326m with the BL680c G5 server 
blade, the option ROM must be updated to 
NC326m Boot code version 3.28 and C Class 
option ROM 1.2.8 or higher. 
NC360m, NC364m  C Class option ROM 1.0.11 
NC532i, NC532m 
Boot code version 5.0.11 and Option ROM 
MBA version 4.5.20 
HP NC-Series Broadcom 1Gb and 10GbE 
Multifunction Drive for Linux version 5.0.19-1 
HP NC-Series Broadcom 10GbE Multifunction 
Driver for Windows Server version 5.0.32.0 
NC362i  Supported 
NC542m  BIOS version 1.17-2 
Minimum hardware revision required: 488074-
B22. 
QLogic QMH2462 4Gb 
FC HBA 
For ProLiant server blades, use QLogic multiboot 
image 1.81af or higher. 
HP Emulex LPe 1105-HP 
4Gb FC 
Emulex boot-pair 6.03a7, Firmware 2.80a4 or 
higher 
QLogic QMH2562 8Gb 
FC HBA 
For ProLiant server blades, use QLogic multiboot 
image 2.14af or higher. 
HP Emulex LPe 1205-HP 
8Gb FC HBA 
Emulex Universal Boot image 6.03a7, Firmware 
1.11a5 or higher 
* Use the HP Gigabit Server Adapter Firmware Upgrade Utility for c-Class Blades version 1.10 on the HP website 
(http://www.hp.com/cgi-bin/hpsupport/index.pl
) or one of the online methods available for the OS. To find the 
online update method for your OS, go to the HP website (http://www.hp.com/go/bladesystemupdates
) and search 
for Server Blade Software & Updates. 
Version 2.31 of HP Virtual Connect Manager checks the server ROM image version and displays an 
incompatible state only for server blades that have a VC Server Profile assigned and are using 
incompatible server ROM versions. Version checking of mezzanine card firmware is not available, so be 
sure to verify that the mezzanine card firmware is up-to-date. 
Server blades and mezzanine cards that do not meet the required firmware versions do not accept Virtual 
Connect-assigned parameters such as MACs and WWNs properly, and therefore maintain factory 