HP Virtual Connect Version 3.01 Release Notes
Known issues  13 
On some combinations of Firefox web browser, Adobe Flash Player, and Operating System, the 
Adobe Flash Player will cause the Firefox web browser to crash unexpectedly - especially if there are 
multiple versions of the Flash Player Plugin installed with Firefox or if there is an older/unsupported 
version of the Flash Player Plugin (e.g. such as Flash v8.0) installed with Firefox, even if the 
older/unsupported version of the Flash Plugin is disabled. It is recommended that Virtual Connect 
3.0x users install only 1 supported version of the Adobe Flash Player Plugin with their Firefox web 
browser.  
Depending on the installed versions of the Firefox, Adobe Flash Player, and OS (for example: 
Combination of Firefox v3.5.9, Adobe Flash v9.0/v10.0, on GNU Linux v2.6.9) certain fix patches 
from Adobe for the Adobe Flash Player may be needed. For the latest information on fix patches 
from Adobe for the Flash Player Plugin, see the Adobe website 
(http://www.adobe.com/support/security/index.html#flashplayer
). 
Also users might experience problems with the Firefox browser hanging or crashing and then 
showing the "failed to create MSXML object" error. This is a known issue with XSLT transformations 
the Firefox browser. See the information at the following URL's about downloading and installing a 
patch for your specific version of the Firefox browser at this Mozilla website 
(http://www.mozilla.org/security/announce/2009/mfsa2009-12.html
) or this Mozilla website 
(http://www.mozilla.org/security/known-vulnerabilities/firefox30.html
). 
•  If the VC Domain is configured for double dense Server mode, and a profile is assigned to an empty 
server bay, and then a hot plug of a single dense server into that server bay will result in the profile 
not being activated. Recovery is to unassign the profile and reassign. 
Firmware update 
HP BladeSystem c-Class Virtual Connect Support Utility v 1.5.0 is now required to install the HP VC 3.0x 
firmware package.  
For more information on installing the firmware, see the HP BladeSystem c-Class Virtual Connect Support 
Utility release notes on the HP website (http://www.hp.com/go/bladesystem/documentation
). 
IMPORTANT: When upgrading the HP VC 4Gb FC firmware from version VC-FC 1.2x to 
version VC-FC 1.40, the VC-FC module can drop connectivity temporarily during the 
activation process. A redundant customer configuration experiences a failover with no loss of 
application connectivity to the fabric.  