HP Virtual Connect Version 3.30 Release Notes
Known issues  16 
Known issues 
New issues 
Issue 
Upgrading Virtual Connect firmware from v3.xx to v3.30 might cause a loss of the VC domain configuration. 
During the activation phase, the firmware update process might terminate abnormally and leave the domain 
in an unconfigured state, resulting in an outage. 
Only VC domains running firmware v3.xx, upgrading to v3.30, and fitting certain criteria are potentially 
affected by this issue. For more detailed information, see Customer Advisory c03057267 on the HP website 
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03057267). 
Issue 
Upgrading VC FlexFabric firmware from 3.15, 3.17, or 3.18 to a newer version might result in a temporary 
Fibre Channel over Ethernet (FCoE) outage. 
This behavior is limited to systems using HP ProLiant or Integrity server blades with a FlexFabric Mezzanine 
adapter and a corresponding FCoE connection to an HP VC FlexFabric 10Gb/24-port module. This 
behavior does not appear for FCoE connections using an embedded FlexFabric adapter (LOM). 
For more detailed information, see Customer Advisory c02950493 on the HP website 
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02950493). 
Issue 
The HP VC 8 Gb 24-Port FC Module does not respond to the HP Insight Control cpqHoGUID MIB request and 
is reported as an error. 
Workaround 
Remove the FC module from the query. 
Issue 
HP Systems Insight Manager might incorrectly identify the HP VC 8 Gb 24-Port FC module as a SAN switch 
due to the incorrect value returned in the SysObjectOid. 
Issue 
Unassigning the profile from an auxiliary bay in a BL8x0c i2 server blade clears the connections on the 
auxiliary blade. 
Issue 
In expanded VLAN mode, the number of allowed connections to a Flex-10 server port is 162. If a profile has 
more than 162 connections defined on a physical Flex-10 port, the port is disabled when the profile is 
applied and the port status is displayed as disabled. 
Issue 
For HP Integrity BL890c server blades installed in an HP c3000 enclosure with FC mezzanine cards installed 
in the 3rd and 4th blades, FC profile connections entries are not mapped or usable. 










