HP Virtual Connect Version 3.61 Release Notes
Issues and workarounds  6 
New issues 
Issue 
When using IE9 to activate the VC GUI, there is no error message when executing without Flash Player. 
Issue 
The VC Unknown (unmanaged) module states (Operational, VC, OA, Comm) are not being displayed in a 
consistent manner. 
Issue 
HP VC Flex-10 and FlexFabric modules may experience an extended timeout when re-establishing a Link 
Aggregation Group (LAG). This issue may increase chances for encountering a ping loss, and the likelihood 
of encountering a lost ping also increases with the number of the port members in the LAG that are being 
recovered or reintegrated. 
Issue 
When one of the uplink ports X1–X4 on the FlexFabric module is not configured for FC or is configured for 
Enet, but has an FC SFP inserted into the SFP cage, the "Connector Type" displayed by VCM and the 
information displayed in the detailed statistics screen are not consistent. 
Issue 
Changing uplink ports in a SUS removes SmartLink settings on all vNets. 
Issue 
If the Primary VC module is still unable to acquire an IP address after all retries have been exhausted, VCM 
incorrectly clears the module configuration. If VCSU is used to check the VC health state, VCSU reports that 
the module is not configured. 
Issue 
VC 3.61 release is still exposed to the security vulnerability CVE-2010-4180. The security concern reference 
can be found on the NIST website (http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2010-4180). 
Issue 
The Virtual Connect Manager CLI interface does not allow creation of the local user account with passwords 
containing the "|" (pipe) character. 
Workaround 
Use the VCM GUI to create local user accounts with passwords containing the "|" (pipe) character. 
General issues 
Issue 
While performing OA fail over events, the GUI prompt for “restoring OA credentials” is delayed longer than 
expected. The GUI displays the message “Web browser unable to communicate with VCM, please close the 
browser and re-connect”. The GUI might also display additional errors. 
Workaround 
Start a new VCM GUI session and OA credentials can be restored successfully. 
Issue 
The GUI fabric status is green for uplinks linked to the Ethernet switch, even though the port type is FC and 
FC SFPs are installed. 