HP Virtual Connect Enterprise Manager 6.3 CLI Guide
Table 17 Parameter descriptions for -set fcoe-connection (continued)
OptionalRequiredDescriptionParameter
x
IMPORTANT: The
-customspeed parameter
is required if the speed type
is custom.
User-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.
-customspeed
xControls whether the FC
HBA port is enabled for
SAN boot and affects the
BIOS boot order. Valid
values include the following:
• Usebios
• primary
• secondary
• disabled
Only one boot parameter is
allowed per FCoE
connection.
-bootpriority
x
IMPORTANT: The
-bootport parameter is
only required when the
bootpriority parameter
is set to either primary or
secondary.
The target world wide port
name (WWPN) of the
controller interface on the
Fibre Channel storage
target. The port name is a
64-bit identifier in the
format:
NN:NN:NN:NN:NN:NN:NN:NN
The designation N stands for
a hexadecimal number.
-bootport
x
IMPORTANT: The
-bootlun parameter is
only required when the
bootpriority parameter
is set to either primary or
secondary.
The logical unit number
(LUN) of the volume used for
SAN boot. Valid values
include an integer from
0-255 or 16 hexadecimal
digits (HP-UX only).
-bootlun
Output
The function returns the result of the set operation or a jobid if –nb is specified.
Examples
• Change the fabric of a FCoE SAN fabric connection:
vcemcli -set fcoe-connection –profilename MyProfile –portnumber 1
–fabric SAN_5
• Set a FCoE SAN fabric connection to unassigned:
vcemcli -set fcoe-connection –profilename RedProfile –portnumber 2
–fabric ""
42 Using VCEM commands