Replacing VC Modules

5
8. Recreate the server profile SAN connections in VCEM.
CAUTION:
The VC and VCEM identifiers (WWNs) associated with the removed server profilesFC connections can be assigned to different
server ports or slots in the recreated server profile SAN connections using FCoE Connections. Recreating the SAN connections in
the server profile means that the newly created connections will be assigned new WWNs.
a. Select VC Domain in the first filter and select the VC Domain name (with the replaced VC modules) in the second
filter.
b. For each server profile that belongs to the VC Domain (with replaced VC FC modules) do the following:
i. Ensure that the server is powered off.
ii. Click Edit and recreate the necessary SAN connections, or assign the existing connections to the new
fabrics depending on your replacement scenario. Wait for the job to complete successfully.
iii. Power up the server.
Technology for better business outcomes
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and
services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
HP shall not be liable for technical or editorial errors or omissions contained herein.
712359-B21 Edition 2, October 2012