FCoE Cookbook for HP Virtual Connect Version 4.20 Firmware Enhancements May 2014

12
Virtual Connect Restrictions
The following restrictions apply to VC modules and switches from different vendors:
Up to 32 FCoE networks can be associated with any single set of uplink ports using the Multi-FCoE Network per Uplink
Set support in VC 4.20 or later.
With multi-FCoE Network per Uplink Set support, customers can benefit from Virtual SANs (VSANs) support but can
also have the ability to provide connectivity to multiple types of SAN from the same Virtual Connect set of ports.
Figure 3: Virtual Connect SUS configuration when using FCoE networks
SUS-1
FCoE-1
VLAN-30
VLAN-20
VLAN-10
LACP
Lossless FCoE Networks
VC Ethernet networks
Converged-SUS defined to pass
FCoE traffic and traditional
Ethernet traffic
FCoE-2
FCoE-3
FCoE-capable Shared Uplink Set (SUS) is used to allow concurrent Ethernet and lossless FCoE traffic.
Figure 4: Sample of a Virtual Connect SUS with 2xFCoE networks and 3xEthernet networks
FCoE
Networks
Ethernet
Networks
Lossless
o An FCoE network cannot be created independently outside of a Shared Uplink Set.
o The number of FCoE networks is additionally limited by the 1000 networks Virtual Connect domain limit.