FCoE Cookbook for HP Virtual Connect Version 4.20 Firmware Enhancements May 2014

18
Considerations
In this scenario, the Nexus switches must operate as Fiber Channel Forwarders (FCF). This is the default Cisco Nexus 5xxx
Series switches mode, it’s also called the fabric mode. In this mode, the switch provides standard Fibre Channel
switching capability and features.
Figure 11: Cisco Nexus 5xxx switches operating as FC Forwarder (FCF)
VF_Ports
VN_Port
VF_Port
VN_Port
Virtual Connect
(FIP Snooping mode)
FCF
Lossless Ethernet
network
FCoE
Storage
Array
FCoE
Dual-Hop FCoE
Nexus 5xxx
Series
(FCF Mode)
VN_Port
Native FC
FC
Storage
Array
N_Port
F_Port
Server 2
(ENode)
Server 1
(ENode)
Converged Ethernet/FCoE
FC
FCoE
This cookbook provides only basic Cisco guidelines and configuration steps, for a more complete and detailed list of
Nexus FCoE configuration guidelines, refer to the Fibre Channel over Ethernet Configuration Guides available at
http://www.cisco.com/c/en/us/support/switches/nexus-5000-series-switches/products-installation-and-
configuration-guides-list.html
For information on Nexus FCoE supported configuration and design with Virtual Port Channel (vPC), refer to:
Data Center Design with Cisco Nexus Switches and Virtual PortChannel
http://www.cisco.com/en/US/products/ps9670/products_implementation_design_guides_list.html
Configuring Storage Array for FC/FCoE is beyond the scope of this document, consult your Storage Array
documentations.