FCoE Cookbook for HP Virtual Connect Version 4.20 Firmware Enhancements May 2014

75
Figure 26: Cisco Nexus 5xxx switches operating as an NPV Gateway
N_Port
VF_Ports
VN_Port
Virtual Connect
(FIP Snooping mode)
Native FC
Lossless Ethernet
network
FC
Storage
Array A
F_Port
N_Port
Cisco
MDS
(NPIV Enabled)
FC
Storage
Array B
TF_Ports
F_Port
Dual-Hop FCoE
Nexus 5xxx
Series
(NPV Mode)
SAN
Port Channel
with Trunking
Port Channel
VSAN A
VSAN B
VN_Port
FCoE
VLAN A
FCoE
VLAN B
FCoE
Gateway
TNP_Ports
NPIV
Converged Ethernet/FCoE
FC
Server 2
(ENode)
Server 1
(ENode)
This cookbook provides only basic Cisco guidelines and configuration steps, for a more complete and detailed list of
Nexus FCoE configuration guidelines, refer to the Fibre Channel over Ethernet Configuration Guides available at
http://www.cisco.com/c/en/us/support/switches/nexus-5000-series-switches/products-installation-and-
configuration-guides-list.html
For information on Nexus FCoE supported configuration and design with Virtual Port Channel (vPC), refer to:
Data Center Design with Cisco Nexus Switches and Virtual PortChannel
http://www.cisco.com/en/US/products/ps9670/products_implementation_design_guides_list.html
Configuring Storage Array for FC/FCoE is beyond the scope of this document, consult your Storage Array
documentations.
Requirements
Refer to SPOCK C-Series FCoE Switch Connectivity stream at
http://h20272.www2.hp.com/Pages/spock2Html.aspx?htmlFile=hw_switches.html for information on:
Minimum NX-OS version
Minimum Virtual Connect firmware version
HP FlexFabric Adapter Firmware and driver
Note: FCoE requires the Nexus Storage Protocols Services license (FC_FEATURES_PKG). This license is an option which
is activated when the Nexus switch is shipped from Cisco.
Guidelines
Since the Nexus is running in NPV mode, it is mandatory to connect the Nexus switches to a native FC SAN
infrastructure.
FC/FCoE-based Storage targets cannot be connected to the Nexus switch when running in NPV mode.