FCoE Cookbook for HP Virtual Connect Version 4.20 Firmware Enhancements May 2014

92
Note: The MAC Address of the FCoE adapter is found under the Virtual Connect Server Profile:
Create a virtual Fibre Channel interface for the second Blade server
o interface vfc 2
o description vfc for Server-2
# Bind it to the MAC address of the second Blade server FCoE adapter 1
o bind interface Ten-GigabitEthernet1/0/12 mac 0017-a477-bc46
# Assign it to the FCoE VSAN
o port trunk vsan 200
Option 2: Configuration with a bridge aggregation between VC and 5900.
Create a link-aggregation interface to connect to Virtual Connect Bay 1
o interface bridge-Aggregation 20
o description Aggregation to VC-Bay1-X3/X4
o link-aggregation mode dynamic
# Enable Spanning Port Fast
o stp edged-port
# Assign the interface to VLAN 200 (FCoE) and VLAN 1,10,20 (Ethernet traffic) as a trunk port
o port link-type trunk
o port trunk permit vlan 1 10 20 200
Associate each interface to the link-aggregation
o interface range te 1/0/12 te 1/0/14
o port link-aggregation group 20
# For DCBX:
Enable LLDP on the interface, and enable the interface to advertise DCBX TLVs
o lldp enable
o lldp tlv-enable dot1-tlv dcbx
Apply the QoS policy named DCBX to the outgoing traffic
o qos apply policy DCBX outbound