HP Virtual Connect 3.70 Release Notes

Fixes 6
o
Option to disable local account access when LDAP, RADIUS, or TACACS+ authentication is
enabled
o Increased the default VCM local user account minimum required password length
o SNMP access security to prevent access from unauthorized management stations
SmartLink failover improvements
IGMP “NoFlood” option when IGMP snooping is enabled
Browser support:
o Internet Explorer 8 and 9
o Firefox 10 and 11
Firmware upgrade rollback from a previous firmware upgrade without domain deletion
Fixes
The VC 3.70 release resolves the following issues:
Resolved an issue where a non-user friendly SOAP error message appeared in the GUI after a DELETE
DOMAIN confirmation. This might have happened when a user logged in with multiple sessions tried to
log out from one session (either a tab or window), or if another user deleted the VC domain.
Resolved an issue where the output from the CLI show uplinkset command was not sorted by vNet
name or VLAN ID.
Resolved an issue where VCM incorrectly cleared the module configuration of the Primary VC module
and was still unable to acquire an IP address after all retries were exhausted. If VCM incorrectly cleared
the module configuration and VCSU was used to check the VC health state, VCSU reported that the
module was not configured.
Resolved an issue where changing uplink ports in a SUS removed SmartLink settings on all vNets.
Resolved an issue where the "Connector Type" displayed by VCM and the information displayed on the
Detailed Statistics screen were not consistent when one of the uplinks ports X1-X4 on the FlexFabric
module was not configured for FC or was configured for Enet but had an FC SFP transceiver inserted
into the SFP cage.
Resolved an issue where the VC Unknown (unmanaged) module states (Operational, VC, OA, and
Comm) were not being displayed in a consistent manner.
Resolved an issue where, when a profile had more than 162 connections, the maximum number
allowed, defined on a physical Flex-10 port, the port was disabled when the profile was applied and
the port status displayed as Disabled.
Resolved an issue where when using the Virtual Connect Support Utility (VCSU) or HP Smart Update
Manager (HP SUM), Virtual Connect firmware upgrades from VC 3.18 or earlier could fail on a single
module when updating to VC firmware later than version 3.51. This fix addressed Customer Advisory
c03395976, which can be found on the HP website
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03395976).
Resolved an issue where PXE, iSCSI, or FCoE boot could fail to be invoked on Gen8 servers.