HP Virtual Connect for c-Class BladeSystem Setup and Install Guide

HP Virtual Connect Manager 89
Advanced SAN Fabric Settings
Login Re-Distribution
When creating or editing a SAN fabric using HP VC FlexFabric Modules in a FabricAttach fabric, select the
Show Advanced Settings checkbox to select the login re-distribution:
Manual Login Re-DistributionDefault for all FC modules. You must initiate a Login Re-Distribution
request through the VC GUI or CLI interfaces. You might re-distribute logins if an uplink that was
previously down is now available, if you added an uplink to a fabric, or if the number of logins through
each available uplink has become unbalanced for any reason.
Automatic Login Re-DistributionWhen selected, the VC FlexFabric module initiates Login
Re-Distribution automatically when the specified time interval expires. For more information about
setting the time interval, see "Fibre Channel Settings (Misc.) screen" in the user guide.
The automatic option is only available on FlexFabric modules in a FabricAttach fabric and enables you to
specify an interval, in seconds, for the length of time the previously offline links must be stable before the
module can re-distribute logins. Login re-distribution is not supported for DirectAttach fabrics.
FCoE Connection Speed
To change these settings, click the selection box, and then select a setting (100Mb to 8Gb):
Set a custom value for the Preferred FCoE Connection Speed. This value is the default speed for server
profile connections mapped to this fabric. The server administrator can override this setting on an
individual profile connection.
Set a custom value for the Maximum FCoE Connection Speed. This value is the maximum speed for server
profile connections mapped to this fabric.
To see how logins are currently distributed on the VC-FC module, navigate to the Interconnect Bays Status
and Summary screen and select the desired VC-FC module. A new Uplink Port column is added to the Server
Ports section of the screen.
To see how logins are currently distributed on the VC FlexFabric module, navigate to the Interconnect Bays
Status and Summary screen and select the desired VC FlexFabric module. A new SAN Uplink Port column is
added to the Server Ports tab.
You can also see how logins are currently distributed on the VC-FC or FlexFabric modules by logging in to the
upstream FC SAN fabric switch.