HP Virtual Connect for c-Class BladeSystem Setup and Install Guide

Planning the installation 9
507017-B21, 507019-B21, 681840-B21, 681842-B21 and 681844-B21. For information on updated
SKUs, see the QuickSpecs on the HP website (http://www.hp.com/go/productbulletin).
VC-Enet modules enable connectivity to data center Ethernet switches. VC-Enet modules can also be directly
connected to other types of devices, such as printers, laptops, rack servers, and network storage devices.
The VC-FC and FlexFabric modules enable connectivity of the enclosure to data center FC switches. Every FC
fabric is limited in the number of switches it can support, but the VC-FC and FlexFabric modules do not
appear as switches to the FC fabric and do not count against FC fabric limits.
A basic VC domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 16 servers (or
up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem c3000 Enclosure
for a total of 8 servers (or up to 16 servers if the double-dense option is enabled). For more information on
the double-dense option, see "Double-dense server bay option" in the user guide. Within the domain, any
server blade with the requisite LAN or SAN devices can access any LAN or SAN connected to a VC module,
and a server blade of a given processor type (Integrity or X86) can be used as a spare for any server blade
of the same processor type within the same enclosure, as long as the server has the requisite number and type
of connections. Using the network access groups feature, the network administrator can clearly define a
separation of networks based on their allowed functionality and prevent the server administrator from
assigning specific network combinations in the same server profile.
By stacking (cabling) the VC-Enet modules together within the domain and connecting the VC-FC or
FlexFabric module FC uplinks on the same bay of all enclosures to the same FC switch, every server blade in
the domain can be configured to access any external network or fabric connection. With this configuration,
you can use VCM to deploy and migrate a server blade profile to any server in the Virtual Connect domain
without changing external LAN or SAN configurations.
Beginning with VC 4.10, the FTP service on VC-Enet modules is disabled by default. The VCSU software
temporarily enables and disables the FTP service during firmware upgrades of VC-FC modules as needed.
More recent versions of VC use SFTP instead of FTP for firmware upgrades.
Each version of VC is tested and supported with one or more SPPs. For a list of supported SPPs that must be
installed, see the VC release notes.
VC module supported firmware
The following table lists all Virtual Connect modules and the highest firmware supported on that module.
Module Highest VC firmware supported
HP Virtual Connect FlexFabric-20/40 F8 Module
4.20
HP Virtual Connect Flex-10/10D Module
4.20
HP Virtual Connect FlexFabric 10Gb/24-port Module
4.20
HP Virtual Connect Flex-10 10Gb Ethernet Module
4.20
HP Virtual Connect 8Gb 24-Port Fibre Channel Module
4.20
HP Virtual Connect 8Gb 20-Port Fibre Channel Module
4.20
HP Virtual Connect 4Gb Fibre Channel Module
4.20
HP 4Gb Virtual Connect Fibre Channel Module
4.01
HP 1/10Gb-F Virtual Connect Ethernet Module
3.60
HP 1/10Gb Virtual Connect Ethernet Module
3.60