HP Virtual Connect for c-Class BladeSystem Version 4.01 User Guide

Table Of Contents
Virtual Connect fabrics 148
To perform a server profile migration of a SAN-booted server between enclosures directly attached to a 3PAR
storage system in the VC multi-enclosure environment, you must perform the following steps manually:
1. Power off the server.
2. Un-assign the server profile.
3. Change the Primary and Secondary Target WWNs in the FC Boot Parameters section of the profile to
reflect the WWNs of the 3PAR storage array ports directly connected to the destination enclosure. For
more information about the FC boot parameters, see "Fibre Channel boot parameters (on page 199)."
4. Assign the profile to the destination location.
5. Power on the destination server.
Double-dense mode
In double-dense mode, bays 7 and 8 must contain the same type of VC-FC or FlexFabric module as bays 5
and 6. When a fabric is created on bay 5 or 6, the corresponding uplink ports from bays 7 or 8 are also
considered part of the fabric. This allows connectivity from the B-side of the server.
Managing fabrics
Use the following screens to manage fabric settings:
Define SAN Fabric screen (on page 149)
o Define a SAN fabric, including selecting login re-distribution for SAN fabrics using HP VC
FlexFabric 10Gb/24-port Modules
SAN Fabrics (External Connections) screen (on page 156)
o View of list of SAN fabrics with external connection information
o Add, edit, or delete a fabric
o Redistribute logins on a SAN fabric
SAN Fabrics (Server Connections) screen (on page 158)
o View a list of SAN fabrics with server connection information
o Delete a fabric
o Redistribute logins on a SAN fabric
o Define a SAN fabric
Edit SAN Fabric screen (on page 154)
o Modify a fabric name
o Set the uplink port speed
o Change the login re-distribution
o Add or delete an uplink port
Fibre Channel Settings (Misc.) screen (on page 159)
o Set the time interval to wait after a link becomes unstable before automatic redistribution occurs
within the fabric