HP Virtual Connect 3.70 Release Notes Abstract This document provides Virtual Connect release information for version 3.70. This document supersedes the information in the documentation set released with version 2.3x, 3.0x, 3.1x, 3.30, 3.51, and 3.60. This document is intended for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Confidential computer software.
Contents Update recommendation ............................................................................................................... 4 Supercede information .................................................................................................................. 4 Product models ............................................................................................................................. 4 Operating Systems ...................................................................
Update recommendation Update Recommendation: Recommended Supercede information Supercedes: 3.60 Product models Virtual Connect 3.
Languages Languages supported for this release: English, Japanese Enhancements Version 3.
o Option to disable local account access when LDAP, RADIUS, or TACACS+ authentication is enabled o Increased the default VCM local user account minimum required password length o SNMP access security to prevent access from unauthorized management stations • SmartLink failover improvements • IGMP “NoFlood” option when IGMP snooping is enabled • Browser support: • o Internet Explorer 8 and 9 o Firefox 10 and 11 Firmware upgrade rollback from a previous firmware upgrade without domain deletion
• Resolved an issue where the GUI fabric status was green for uplinks that were linked to the Enet switch, even though the port type was FC and FC SFP transceivers were installed. • Resolved security vulnerability CVE-2010-4180. • Resolved an issue where HP VC Flex-10 and FlexFabric modules could experience an extended timeout when re-establishing the Link Aggregation Group (LAG).
On the Ethernet Networks (Server Connections) screen the "Go to Network" action does not open the Edit Network screen. Workaround Go to Ethernet Networks (External Connections) screen and perform the "Edit" action for that network. Issue HP recommends that the “Prevent flooding of unregistered multicast traffic” option remains disabled when using VCEM to manage the VC domain with the “VCEM Compatibility Mode” set to a VC firmware version earlier than 3.70.
far in the future, the module might stop renewing the lease, which can potentially result in duplicate IP address assignments in the network. Issue An extra button appears when using Internet Explorer 8 to view the Detailed Statistics screen for FC uplink ports on a VC FlexFabric module. If you click Back to Previous Page, the tabs in the main window change. To return to the previous screen, simply close the browser window.
The timestamp for SNMP traps from VC-FC interconnect modules is not in sync with the timestamp kept by Virtual Connect Manager. Issue Even though the VC iSCSI boot from SAN implementation allows you to select LUN values from 0-255, the adapter firmware limits the supported LUN values to 0-8 Issue Under certain circumstances, the checkpoint status icon in the GUI persists for a long time and is not cleared. The CLI also shows a "Checkpoint Status: Invalid" status in the show domain command output.
• The Virtual Connect GUI requires a minimum of 512 MB of available memory to operate efficiently. • To operate with HP VC 8Gb 20-Port FC Modules, all HP Emulex LPe 1205 8Gb FC HBAs that are revision A (identified by label EDC A-4904) must perform a CFL region 19 flash update. For download and installation instructions, see the LPe1205 product page on the HP website (http://www.hp.com). • Virtual Connect Manager version 3.70 requires Adobe Flash Player 10.x or higher before you can log in.
IMPORTANT: When upgrading the HP VC 4Gb FC firmware from version VC-FC 1.2x to version VC-FC 1.4x, the VC-FC module can drop connectivity temporarily during the activation process. A redundant customer configuration experiences a failover with no loss of application connectivity to the fabric. Virtual Connect firmware VC 8Gb 24-Port FC VC 4Gb FC firmware VC 8Gb 20-Port FC firmware within Virtual firmware within Virtual within Virtual Connect Connect Connect v1.31 1.20 — — v1.32, v1.34 1.21 — — v2.
The firmware versions and software versions listed in this section have been tested as a solution set using HP Service Pack for ProLiant 2012.08.0 as a baseline, and are fully supported by HP. For Virtual Connect version 3.70, HP recommends the use of SPP version 2012.08.0 with updates for specific components of the solution.
HP Integrity Server Blade Version 04.31 HP Integrity BL860c (http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?lang=en&cc=us&pro dNameId=3351095&prodTypeId=3709945&prodSeriesId=3331044&swLang=13&taskId=135& swEnvOID=4001) 04.31 HP Integrity BL870c (http://h20000.www2.hp.com/bizsupport/TechSupport/DriverDownload.
Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.