HP Virtual Connect for c-Class BladeSystem Version 3.00 Setup and Installation Guide for HP Integrity BL8x0c i2 Series Server Blades

Component identification 20
Item LED description Status
7
X7/X8 shared port
activity
Green = Port is active.
Off = Port is inactive.
8 X7/X8 port status
Green = Port is configured and operating
as an uplink port connected to a data
center fabric.
Amber = Port is operating as a stacking
link interconnecting Virtual Connect
modules.
Blue = Port locator (PID)
Off = Unconfigured
9 X1/X6 port status
Green = Port is configured and operating
as an uplink port connected to a data
center fabric.
Amber = Port is operating as a stacking
link interconnecting Virtual Connect
modules.
Blue = Port locator (PID)
Off = Unconfigured
10
X1 shared port
activity
Green = Port is active.
Off = Port is inactive.
Shared port operation
Port X1 (10BASE-CX4) and Port X1 (SFP+)
Port X1 (10BASE-CX4) is multiplexed with Port X1 (SFP+). Either the CX-4 port is active or the SFP+ port is
active, but not both. The triangle LED underneath each port indicates which port is active. The SFP+ port
always has precedence over the CX4 port.
If there is a module installed in the SFP+ port, the SFP+ port is the active port.
o The LED under the SFP+ port is on.
o The LED under the CX4 port is off.
If there is no module installed in the SFP+ port, the CX4 port is the active port.
o The LED under the CX4 port is on.
o The LED under the SFP+ port is off.
Port X7 and port X8
Port X7 (SFP+) and port X8 (SFP+) are each multiplexed with an internal 10Gb interface cross-link,
which is provided on the enclosure midplane between two horizontally adjacent VC modules to
establish stacking links. Either the port is active or the internal cross-link is active, but not both. The
triangle LEDs underneath ports X7 and X8 indicate whether the SFP+ port is active or the internal
cross-link is active. The SFP+ port always has precedence over the internal cross-link port. Port X7 is
shared with internal cross-link 1, and Port X8 is shared with internal cross-link 2.
If there is a module installed in the SFP+ port, the SFP+ port is the active port.
The LED under the SFP+ port is on.